20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
PROFINET Protocol
PROFINET N
ETWORK
C
ONFIGURATION
95
7.6 Set the NR60E2 Parameters
The NR60E2 uses one of five telegrams to communicate cyclically with the controller. The format of the
telegrams is explained in the
Reference chapter, starting on page 83.
With the NR60E2 icon selected on the PROFINET bus, click on the “Device view” tab. The view in the Hard-
ware Catalog will change.
1) In the Device overview pane, right click on “Module Access Point” and select “Properties” from the
resulting drop down list.
2) In the “Module Access Point [Module Access Point]” pane at the bottom of the screen, select “Module
Parameters”. The “Standard parameters (Encoder Profile)” will appear with the parameters set to their
default values. The parameter values can be changed here. The NR60E2 parameters are explained in the
section, starting on page 15.
Figure T7.5 Setting NR60E2 Parameters
Summary of Contents for NR60E2
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual E2 Technology E2 Technology Manual 940 0D161...
Page 6: ...TABLE OF CONTENTS NR60E2 User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Page 20: ...NR60 SPECIFICATIONS NR60E2 User Manual ADVANCED MICRO CONTROLS INC 20 Notes...
Page 44: ...PROTOCOL SPECIFIC INFORMATION NR60E2 User Manual ADVANCED MICRO CONTROLS INC 44 Notes...
Page 52: ...IMPLICIT COMMUNICATIONS WITH AN EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 52 Notes...
Page 58: ...IMPLICIT COMMUNICATIONS WITHOUT EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 58 Notes...
Page 70: ...CIP POSITION SENSOR OBJECT EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 70 Notes...
Page 90: ...PROFINET CYCLIC DATA FORMATS PROFINET Protocol ADVANCED MICRO CONTROLS INC 90 Notes...
Page 98: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...