20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
Output Data Format
5
65
Command Block 7: Program Die Protection Parameters
This block allows you to program the die protection parameters.
Figure 5.10 Command Block 7
Command Word Bits
Bit 5:
Delete All LS Data.
Setting this bit to ‘1’ will delete all of the parameter values associated with the
Limit Switch Output given in word 1. This includes all setpoints, ON/OFF advance values, and the
parameters associated with output enabling.
Bit 6:
Delete Die Protection Data.
Setting this bit to ‘1’ will delete all of the Die Protection parameters
associated with the input given in word 2. Input ANDing parameters for the input are left unchanged.
Bit 8:
Program Fault Output.
If this bit is reset to ‘0’, the output associated with this Die Protection Monitor
will be left unchanged. If this bit to set to ‘1’ the output associated with this Die Protection Monitor
will be set to the value in word 1. If word 1 is set to a value of zero, no output will be associated with
this Die protection monitor.
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
1024
T
ransmit Bit
0
0
0
0
App
ly W
o
rd
s 2 & 1
2
Ap
ply
W
o
rd
s 2 - 1
1
Apply W
o
rd
1
0
Delete Die Protection
Delete Al
l
Clear Error
0
1
1
1
1
1025
Fault Output Point being programmed (Range of 0, 1 to 16)
If ‘0’, no output is associated with this die protection block.
2
1026
Die Monitoring Input Point Number (Range of 1 - 16)
3
1027
Check Mode for Input defined in word 3. (Range 0, 1-5)
See Bit 9 description below
4
1028
Check Window 1 Leading Edge Setpoint
(Range of 0 to (
Full Scale Count
-1))
5
1029
Check Window 1 Trailing Edge Setpoint
(Range of 0 to (
Full Scale Count
-1))
6
1030
Check Window 2 Leading Edge Setpoint (Same range as word 4.)
7
1031
Check Window 2 Trailing Edge Setpoint (Same range as word 5.)
8
1032
Check Window 3 Leading Edge Setpoint (Same range as word 4.)
9
1033
Check Window 3 Trailing Edge Setpoint (Same range as word 5.)
10
1034
Check Window 4 Leading Edge Setpoint (Same range as word 4.)
11
1035
Check Window 4 Trailing Edge Setpoint (Same range as word 5.)
12
1036
Die Protection Action Mode (Range or 0 to 3)
See Bit 10 description below
13 - 19
1037-1043
Not Used
Summary of Contents for ANS1 ANYNET-I/O
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Page 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Page 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Page 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Page 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...