I/O Wiring
Relay Board Inputs
The RB-8 relay board has a terminal block that allows you to connect to inputs 1 through 8 on the ANS1. All
eight inputs are
Sourcing Inputs
. The Common pin on the terminal block must be attached to the positive lead
of the power supply that is used to power the sensors. Figure 4.15 below shows how to wire sinking and
sourcing sensors to the RB-8 relay board inputs.
Figure 4.15 Wiring RB-8 Inputs
Relay Board Outputs
Outputs on the RB-7 and RB-8 can be wired as either sinking or sourcing outputs. When wiring to DC relays,
the “+” terminal must be attached to the higher side of the load.
COM
COM
DC Sinking Sensors
DC Sourcing Sensors
+12 Vdc to +24 Vdc
Isolated Power
Supply
Can use the
same supply to
power all inputs
+12 Vdc to +24 Vdc
Isolated Power
Supply
Can use the
same supply to
power all inputs
–
R
PD
Supply
R
PD
12 Vdc
600 to 660 ohm
15 to 24 Vdc
1.74 to 1.80 Kohm
–