www.amcelettronica.com
installation instructions
MOUSE GS
- Rev. 1.0
2
Mouse GS is a dual technology detector consists of a PIR and a microphone for the notification of shock and glass
breakage. It has independent settings for the RIP and the microphone section. It has a maximum range of 7mt for the
microphone section, and approximately 12mt for the infrared. You can adjust the microphone section only for glass bre-
akage, or for shock and glass breakage. It has the ability to have different filterings to accentuate or less the efficiency
in detecting breakages / damage.
It is available in 2 versions:
Standard version
or
Pet immune 10kg version
1. INTRODUCTION
ENGLISH
2. INSTALLATION
- Using a thin instrument (eg mini screwdriver), push the little round button on the front of the detector and open the
cover.
- Remove the PCB from the bottom of the cover relying on the clip in the terminals side.
- Drill the knockouts that you want to use for mounting, or use the swivel bracket (optional).
- Slide the cable through the cable guide on the back of the cover by taking it out of the hole at the top.
- Wire the terminals following the links.
Note 1: The ground clearance recommended for attachment is 2m.
Make sure all DIP switches are in the desired position (see diagram below).
Give supply voltage and wait until the device is operational.
The device is operating when the green LED flashing stops.
Rotate the trimmer so that the sensor detects the movements and breaks at the required distance (“+”
⇒
greater range
“-”
⇒
minor range). After close the sensor.
3. CONNECTIONS AND ADJUSTMENTS - DIP SWITCHES
dip 1
dip 2
off
off
detecting a frequency band (high sensitivity)
off
on
detecting two frequency bands (normal sensitivity)
on
off
detecting a frequency band and an impact (low sensitivity)
on
on
detecting two frequency bands and an impact (very low sensitivity)
dip 3 OFF
Infrared operation - 1 pulse
dip 3 ON
Infrared operation - 2 pulses
TERMINALS AND TRIMMER
+ / -
13.8Vdc detector power supply
MIC
Microphone alarm contact
PIR
Infrared alarm contact
C
Reference common for alarms
TAMPER
Tamper anti opening (N.C.)
Trimmer MIC
Microphone range trimmer
(“ + ”
⇒
greater range “ -”
⇒
minor range)
Trimmer PIR
Infrared range trimmer
(“ + ”
⇒
greater range “ -”
⇒
minor range)
2mt
5mt
7mt
2mt
6mt
12mt
Microphone range
Infrared range
Note: being a detector with microphone, we recommend you install the sensor far from sound sources with
power particularly high.