AMC MOUSE 07/P Installation Download Page 2

www.amcelettronica.com

installation instructions

MOUSE 07

 Dual Technology - Rev. 1.3

2

1. INTRODUCTION

ENGLISH

MOUSE 07 is a 

pet immune 10kg,

 digital dual technology detector. It combines a dual element PIR with temperature 

compensation, and a X band  microwave section with broadcast pulse planar cavity. Thanks to its special algorithm it 

is able to reach a coverage of 15 m and an angle of 90° , ensuring an outstanding immunity to false alarms.  

The detector can work in three different configurations: 

AND: 

alarm is triggered only when detection comes both technologies 

(maximum false alarm immunity)

.

OR:

 as soon as one technology detects, the alarm is triggered. 

OR auto:

 AND-type operation with check of the consecutive alarm from each technology, and alarm notification also 

when one of them is switched off (

ex. after masking or tampering, etc.)

.

Mouse 07 is provided with 

excludible led walk test, alarm memory and separate anti-opening contact

.

  

note: the pet imunity function requires AND mandatory configuration

2. INSTALLATION

- By using a thin screwdriver, push the round tooth on the bottom and open the housing.

- Remove the PCB from the base.

- Use a screwdriver to pierce the knockouts on the side of the base where you wish to attach the detector to the wall 

or use the optional swivel bracket.

- Route the wires via the rear channel into the base and let them pass through the hole on the top of the housing.

- Wire up the terminals following the connections shown in the figure.

REMARK 1: the  advised height from the floor is 2 m.

Verify that all DIPswitches are in the desired position (see next figures).

Supply the detector and wait until  the LED stops to flash. 

Turn the trimmer to adjust the MW range, so as to let the MW detect the movements at the distance you need.

“+”  

 larger range   “-”  

 smaller range

Close the detector and check the range in AND configuration (lighting of the red LED).

Open again the detector and continue with the following adjustements.

N.B. : To avoid  false alarms, it is advised to increase the range not more than necessary.

MEMORY FUNCTION: 

it is active when B/S terminal is open or when a negative voltage is applied on it. A memory 

event is reported by the led lightning. To reset the memory apply on the B/S terminal a positive voltage. Open again 

the terminal to switch on it again. 

3. CONNECTIONS AND ADJUSTMENTS

L - H

general regulation of the range L= low from 3 to 7mt   H = high from 7 to 15mt

OR

OR function activation (switch the dip toward the OR writing)

AUTO

OR auto function activation

MEM

alarm memory activation (green=microwave - orange=infrared - red=both tecnologies 

LED

led walk test activation 

DIP-SWITCH

TERMINALS

+ e -

13.8Vdc detector power supply

B/S

walk-test led control block (positive=led switch off)

N.C.

alarm contact (N.C.)

TAMPER

tamper contact (N.C.)

TRIMMER

TRIMMER

fine range regulation (it depends on 

L - H 

dip position)

remark: every time that the dip-switch position is changed there is a led lightning to confirm the 

operation. 