background image

of false alarms)

 

buzzer with different sounds: 

The sensor has buzzer for violation notify, when is active the buzzer 

emits a sound that is different depending on the direction in which it is violated.

 

Note: that the accuracy of the notification of direction is achieved by placing the appropriate 
blade in the lens on PIR, contained in the package.

 

- recognition of the alarm direction (dip 7 - 8): 

This feature allows the sensor to trig in alarm only 

when traversed in a one direction. After crossing the allowed direction without generating alarms, 
start inhibition time during which it will be possible to re-cross the 

“active” part without the gene 

ration of the alarm. This time is 2 minutes, after which the sensor will return ready. This feature 
allows a user to look out the window or out on the terrace without causing alarm when the system 
is armed.

 

Clearly if the direction of crossing is from outside to inside the sensor will trigger in alarm. 
(requires blade separator see figure)

 

Note: you can choose which side is active alarm. (dip-switch 8)

 

 

3. INSTALLING AND SETTING

 

The sensor is designed to be installed to protect the openings, for example between the window 
and the shutter, or to doors and gates. Due to the high angle of coverage and the ability to rotate 
the lens on the support of the pyroelectric, you can install it in different ways, from top to bottom or 
on one side.

 

 

 

separation blade

 

Summary of Contents for IF16L

Page 1: ...korzystywana do uzyskania dostępu do chronionej strefy bez konieczności rozbrajania systemu Sygnalizacja akustyczna naruszenia Czujka jest wyposażona w sygnalizację dźwiękową w przypadku przejścia przez barierę gdy jest podłączona wytwarza różne dźwięki w zależności od kierunku alarmu UWAGA dokładnie rozpoznanie kierunku alarmu odbywa się dzięki umieszczeniu prawidłowej płytki separacyjnej w socze...

Page 2: ...ych konfiguracjach od góry od dołu lub z boku W celu poprawnego wykorzystania tej funkcji rozpoznawania kierunku naruszenia oprócz ustawienia przełącznika DIP7 i DIP8 należy również odpowiednio założyć soczewkę i ustawić separator wiązki 4 INSTALACJA Wybierz miejsce instalacji czujki zamocuj czujkę za pomocą otworów do mocowania Kabel może być przeprowadzony przez mały otwór jak na rysunku lub jeś...

Page 3: ...macje na temat elementów regulacyjnych wraz z opisem dostępnych funkcji znajdują się w dalszej części instrukcji 7 Zamknąć pokrywę czujnika 8 Podłączyć napięcie zasilania i zaczekać aż dioda w czujnika przestanie migać 5 START I KALIBRACJA Po podłączeniu czujnik potrzebuje około 40 sekund na start i kalibrację W tym czasie naruszenia nie są sygnalizowane Działanie bez ustawień kiedy czujka jest ak...

Page 4: ...ozpoznawanie kierunku alarmu dip7 dip8 Czujnik IF16L wyposażony został w funkcje rozpoznawania kierunku z którego jest naruszany Dzięki tej funkcji możliwe jest zdefiniowanie kiedy ma być generowany alarm Do załączenia tej funkcji służy przełącznik DIP7 W pozycji DIP7 OFF alarm jest generowany niezależnie od kierunku naruszenia natomiast w pozycji DIP7 ON alarm jest generowany tylko przy naruszeni...

Page 5: ... LED that is used as a lamp for different functions As emergency lamp when the terminal LAMP is given a negative via open collector out As presence light if it is associated duration light 40 delay system activation dip4 dip5 Turning ON the DIP introduces a time delay between the instant of the sensor detects the movements and the instant at which trigger the alarm relay After the first violation ...

Page 6: ...e to re cross the active part without the gene ration of the alarm This time is 2 minutes after which the sensor will return ready This feature allows a user to look out the window or out on the terrace without causing alarm when the system is armed Clearly if the direction of crossing is from outside to inside the sensor will trigger in alarm requires blade separator see figure Note you can choos...

Page 7: ...ht for 40 DIP 7 alarm from all direction Alarm from one direction DIP 8 1 2 alarm 2 1 alarm To use the directional system optimally you need to be inserted into the lens on the pyroelectric element separator see figure and install it paying attention to the direction selection dip swtch8 4 INSTALLATION Chooses uitaDieibcatiwT h The cable can go from a tiny hole next to the terminals or if the sect...

Page 8: ...olds After this time the sensor is still ready with lamp in ON mode Each new violation prolong the time of the lamp for 40 recovery time by the alarm is 10 seconds Thus the sensor works correctly even with the lamp on When the lamp is turned off you will have a new calibration of the duration of 20 seconds In case of violations during the calibration time after 30 seconds the sensor trig in alarm ...

Page 9: ...m 25 C to 55 C RFI Protezione Protection 10 V m 20 1000 MHz Led WALK TEST MW and PIR S Cover Housing ABS Dimensioni Dimensions L145 x H37 x P30 mm Installation must be carried out following the local installation norms by qualified personnel The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product system It is recommended to test the operation of the...

Reviews: