DT16

 

installation instructions v1.3

 

 

SPECIFICHETECNICHE/ SPECIFICATIONS/  SPECIFICATIONSTECHNIQUES

 

Alimentazione / Input Voltage

 

9.5  to 15 Vdc

 

Consumo / Current Drain (Alarm/Stand-By)

 

(18 mA / 26mA) @ 13.8 Vdc

 

Portata in lunghezza / Coverage

 

2 - 3,5 m

 

Portata in larghezza / Angle

 

165°

 

Piroelettrico / PIR

 

2 elementi / 2 elements

 

Microonda classe ricevitore / microwave receiver class

 

2

 

Lente (fasci e livelli) / Lens (beams and levels)

 

6 beams on 1 levels

 

Durata allarme / Alarm period

 

4 sec.

 

Antiapertura / Anti-opening

 

 

Contatto di allarme / Alarm’s Contact

 

100 mA - 40 V - 16 

 

Contatto di tamper / Tamper Switch

 

Max 400 mA - 40 Vdc

 

Temperatura di esercizio certificata / certified operating Temperature

 

From  -

10 °C  to +55 °C

 

RFI Protezione / Protection

 

10 V / m (20 /1000 MHz)

 

Led WALK TEST (MW and PIR)

 

 

Cover / Housing

 

ABS

 

Dimensioni / Dimensions

 

L145 x H37 x P30 mm

 

 

EN 50131-2-4 Grade 2 Class 2

 

 

 
 

Installation must be carried out following the local installation norms by qualified personnel.

 

The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.

 

It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and 
due to, but not limited to, any or all of the following: tampering, electrical or communication disruption or improper use, it 
is possible for the product/system to fail to prevent burglary, rubbery, fire or otherwise. A properly installed and maintained 
alarm system can only reduce the risk that this happens.

 

 

 

Summary of Contents for DT16

Page 1: ...kim miganiem diody LED co 2 sek Je li czujka zostanie naruszona podczas tych 2 minut to alarm nie zostanie wygenerowany W ci gu ostatnich 10 sek wtrzymania dioda LED zacznie mruga szybciej co oznacza...

Page 2: ...1 LED wy czony LED w czony DIP 2 1 impuls dla alarmu 2 impulsy dla alarmu DIP 3 2m zasi gu 3 5m zasi gu DIP 4 Alarm dla wszystkich kierunk w Alarm dla jednego kierunku DIP 5 I II II I 4 INSTALACJA I...

Page 3: ...dc ALARM WTYK ALARM 100 mA 40 V 16 ZASILANIE 13 8Vcc26mAMaks 5 START I KALIBRACJA Po pod czeniu czujnik potrzebuje ok 40 sekund na start I kalibracj W tym czasie wszelkie naruszenia nie b d sygnalizow...

Page 4: ...www amcelettronica com DT16 installation instructions v1 3...

Page 5: ...icrowave receiver class 2 Soczewka promie I poziomy Lens beams and levels 6 promieni na 1 poziome Czas alarmu Alarm period 4 sec Ochrona przed otwarciem Anti opening Wtyk alarmu Alarm sContact 100 mA...

Page 6: ...thereanyviolationofthesensorwillnotgeneratealarm Duringthelast10secondsoftheperiodofinhibition theLEDwillbegintoflashrapidlytoindicatethatthesensorwillreturnin theoperatingstatusandwillbeabletogenera...

Page 7: ...alarm DIP 3 2mtcoverage 3 5mt coverage DIP 4 alarm from all direction Alarm from one direction not IMQ certified DIP 5 1 2 alarm 2 1 alarm Tousethedirectionalsystemoptimally youneedtobeinsertedintothe...

Page 8: ...to the appropriate terminals Use the scew to fix the top Inthefigureattheendofmanual youcanseedifferenttypesofinstallation inthecenterofthewindoworonaside Thedrawingsareforguidanceonly soyoushouldalwa...

Page 9: ...www amcelettronica com DT16 installation instructions v1 3 90 90 SIDE VIEW 20cm SIDE VIEW 20cm 120cm 120cm FRONT VIEW FRONT VIEW...

Page 10: ...icata certified operatingTemperature From 10 C to 55 C RFI Protezione Protection 10 V m 20 1000 MHz Led WALK TEST MW and PIR Cover Housing ABS Dimensioni Dimensions L145 x H37 x P30 mm EN50131 2 4Grad...

Reviews: