Ambirad NRV12LR Installation Instructions Manual Download Page 18

18 

 

THE

 LO

CA

L RE

LA

UN

IT

 h

ouses

 an 

inver

ter.

 T

his

conv

erts

 the

 230V

 si

ngle-p

hase 

inpu

int

a

three-

p

h

ase 

230V

 out

put.

 The

 inv

erte

pro

vid

es

 a

soft s

tart to the 

motor, 

which

 e

x

tend

the

 m

ot

or

 li

fe

by m

inim

is

ing t

he s

tart

 cu

rr

ent

.

In

ver

ter

L

o

cal Rela

y

Unit

S

u

p

p

ly

 vi

a Is

ol

ato

r

230V

 5

0Hz 1 Ph

a

S

U

PPL

Y

 VIA 

IS

O

L

ATOR

E

L

ECT

R

IC

AL IN

PUT

23

0V 1

P

 22

A

23

0V 1

P

 22

A

  2

3

0

V

 1P

 30A

FAN TYPE

B8

0

B

160

B

300

L

L

NN

U

V

W1

34

2

D

ra

w

in

g N

o

. :

 90

02

87

 R

5

 L

O

M

Ex

hau

st

Fan

4

-Co

re

 Ar

mo

ur

ed

 o

r

Sc

reen

ed C

able 

1.5

m

m

²

FAN MO

T

OR

230V

 3-P

hase

 S

uppl

y.

Mot

or m

ust

 be 

wir

ed

 DE

LT

A

3 Pha

se

Is

o

lato

r

MPOR

TAN

T

F

o

r Inve

rt

e

r p

a

nels on

ly

(fan ty

pes 

B8

0 / B

160 & B300):

MA

XIM

U

M

 len

g

th of c

a

bl

e between 

inver

ter

and fa

n is 

5m (EM

C

 class 

A

 b

u

ildi

ng) o

r

10

m (EM

C

 c

las

s B bui

lding

).

N

.B

if in do

ubt, do 

not e

xceed 5m.

(HEAT

 1 OUTPUT)

(COMMO

N)

(REMOTE O

N)

(REM

OTE OFF)

(LIVE)

(NEUTR

AL)

NO

T

E

S

:

REM

O

T

E

 SE

NS

O

R

(s

)

 ma

y b

e

pl

ac

e

d

 a

t a

 m

a

x

 d

is

ta

n

c

e

 of 

100m

fr

om

 th

e c

o

ntr

o

l u

n

it, 

us

ing

s

c

ree

ne

d 6

A

 ma

in

s

ca

ble

.

W

ir

in

g s

h

oul

d b

ke

pt

 s

ep

ar

ate

fr

om

 m

a

in

s

 w

ir

ing 

to mi

nim

is

e

no

is

e

 pi

c

k

 up

. S

e

t wi

thi

n

 E

n

gin

e

e

rs

fu

nc

ti

on

s

 fo

r r

e

mo

te

 s

e

ns

or

.

*T

h

e p

ow

er

 s

upp

ly

 is

 no

n-

is

ol

at

e

d,

th

er

ef

o

re al

l w

ir

ing

 t

o th

e co

nt

ro

l mu

st

 b

e

m

a

in

s

 ra

ted.

Low

 Vo

lta

ge

+1

5V DC

B

la

ck B

u

lb

Se

ns

or

(F

AN

 CIRCUIT)

(F

AN

 CIRCUIT)

Bu

rn

er

s

Zone A

Vol

t

Fre

e

No

te

:

Connec

tion

 to

 t

he

burne

rs M

U

S

T

be m

ade 

via

 a

3A

 fus

ed s

pur.

BM

S

230V

 VBur

ner O

N Sig

na

l

 Circ

uit

Volt

 Fr

ee Rem

ote

 ON

THE SOFTWAR

E

 FOR TH

E

 BMS MUST

 ONLY REQUEST A 

LOCKO

U

T

CONDITION WHEN THE SYST

EM IS

 REQU

E

S

TI

NG

 HEAT. I

N

 ADDITI

ON,

IT SHOULD 

ALSO PR

OVI

D

E A

 60s

 DELAY B

E

FORE 

INDI

CATING

LO

CKO

U

T.

 T

H

IS 

IS 

TO

 ALLO

THE S

O

LE

NOI

D

 CO

IL 

TO

 O

PERATE

AF

TER

 IN

IT

IAL SU

P

P

L

Y

 IS CO

N

N

ECTED

 TO THE HEATER,

 WHEN

CALLING FOR THE HEAT VI

THE 

CONT

ROL SYSTEM AND A

R

E

-ST

A

R

T

 A

T

TEMPT I

F

 NEC

C

ESARY.

Not

e

If

 the

 point

 is not

 compli

ed wi

th

the BMS 

will

 receiv

e

 a 

false

re

port of

 t

he 

bur

ner s

tatu

s

.

 Circuit

 Bur

ner #

1

Vo

lt Fr

ee Burne

r Lockou

t

Vo

lt Fr

ee Fan Trip C

irc

uit

 Circuit

 Bur

ner #

2

Vo

lt Fr

ee Burne

r Lockou

t

 Circuit

 Bur

ner #

3

Vo

lt Fr

ee Burne

r Lockou

t

!

!

FUS

E R

A

TI

NG

!

41

40

95

1/L

2/

N

10

6

B1

B0

B2

S/R

0S/R

1

C

SmartCom

Singlezon

e

NEUT

LI

V

E

Figure 4.p. NRV Schematic interconnecting wiring. B80, B160 and B300 three phase fans   
controlled by SmartCom3 via Inverter panel. Individual BMS burner Lockout and VF interface. 

Summary of Contents for NRV12LR

Page 1: ...d Safety at Works Act 1974 or relevant codes of practice In addition the installation must be carried out in accordance with the current IEE wiring regulations BS 7671 BS 6896 Industrial Commercial an...

Page 2: ...onnections 1 6 1 Typical Wiring Schematic 1 6 2 Wiring Details 1 7 Ventilation Requirements 1 8 Exhaust Air Inlet Options 1 8 1 Exhaust Flue Considerations 1 8 2 Ducted Air Inlet Considerations 1 9 Va...

Page 3: ...nt tube The radiant heat emitted from the hot tube is directed downwards by reflectors The remaining interconnecting tube is called the tail pipe and radiates with less intensity The operating tempera...

Page 4: ...amber 1 3 2 2 Subsequent supports are placed approximately 2 8m apart including one at each combustion chamber location This gives a max imum load per support of 24kg 1 3 2 3 A support must always be...

Page 5: ...5 Figure 1 b Clearance for servicing distances to walls and obstacles above Figure 1 c Clearance for servicing distances to obstacles above G G E E Obstacle over burner F End vent module G Burner lid...

Page 6: ...00 770 600 770 Dim A Perimeter reflector mm 305 450 305 450 305 450 Burner Model NRV32LR NRV38LR NRV46LR End vent In line End vent In line End vent Below tube Dim D Without undershield mm 1440 1700 15...

Page 7: ...nd Supply A competent or qualified engineer is required to either install a new gas meter to the service pipe or to check that the existing meter is adequate to deal with the rate of gas supply requir...

Page 8: ...taken to observe the minimum pipe bend diameter minimum 250mm maximum 350mm pipe expansion distance minimum 30mm maximum 70mm as shown in fig e Maximum bend diameter for the hose is 450mm The correct...

Page 9: ...by means of a three pin plug in power connector Live neutral and earth connections should be made via a flexible supply cable to the power connector and routed clear of the heater or tubes The flexibl...

Page 10: ...Burner End Vent Burner 2nd Branch Zone 1 1st Branch Zone 1 1st Branch Zone 2 Isolator Tail Pipe 0 75mm Screened Cable Sensor Zone 2 SmartCom no 2 Slave SC3 MZ 230V 50Hz 13A Mains Supply 0 75mm Screene...

Page 11: ...BLUE DELAY TIMER RED BLUE MAINS INPUT EMC FILTER BLUE GREEN YELLOW BLUE Figure 4 c LR internal wiring diagram End Vent Burner EV Figure 4 d LR internal wiring diagram In line Burner IL MAIN RED FLAME...

Page 12: ...ALVE J S T BLUE 1 2 3 4 5 BLUE DELAY TIMER BLUE BROWN GRN YEL N L3 L2 L1 MAINS INPUT A1 A2 C N O N C RELAY RED EMC FILTER Detail shows either N O or N O contacts MAIN GREY GREEN YELLOW RED FLAME SENSO...

Page 13: ...Figure 4 g LR internal wiring diagram End Vent Burner c w 3 way solenoid valve Figure 4 h LR internal wiring diagram End Vent Burner c w valve N O or N C VF Lockout contacts MAIN GREY GRN YEL RED FLA...

Page 14: ...S L2 RC V S D 1 AI1 0V W T3 U T1 V T2 E L 230V 50HZ 1 Pha SUPPLY MAINS ON LAMP FAN HEALTHY LAMP TO FAN tW tU tV Blue N t1 t2 Brown Fan Trip Circuit A1 A2 t3 t4 11 12 Brown Brown 3 2 1 E E Circuit VF E...

Page 15: ...ge switching inputs to be normally open closed circuit to enable Connect to B0 B1 for remote ON ie BMS time control Connect to B0 B2 for remote OFF ie door interlock remote frost etc The power supply...

Page 16: ...sor The power supply is non isolated therefore all wiring to the control must be mains rated Black Bulb Sensor Note Connection to the burners MUST be made via a 3A fused spur FUSE RATING 41 40 9 5 1 L...

Page 17: ...ON REMOTE OFF LIVE NEUTRAL NOTES REMOTE SENSOR s may be placed at a max distance of 100m from the control unit using screened 6A mains cable Wiring should be kept separate from mains wiring to minimi...

Page 18: ...within Engineers functions for remote sensor The power supply is non isolated therefore all wiring to the control must be mains rated Low Voltage 15V DC Black Bulb Sensor FAN CIRCUIT FAN CIRCUIT Burn...

Page 19: ...ided See BS6896 section 5 2 2 2 2 1 1 8 Exhaust and Air Inlet Options 1 8 1 Horizontal discharge Considerations The vacuum fan must be located as shown in the layout drawing The vacuum fan must have a...

Page 20: ...er duct the main air supply header which is feeding the individual branch ducts and burner end vent supply ducts must have a maximum pressure drop of 0 25 mbar 0 1in wg All joints and seams in the air...

Page 21: ...52 152 152 F 50 97 50 50 G 150 150 150 148 H 295 318 340 380 J 80 90 90 110 K 150 140 140 120 L 240 240 240 240 M 309 303 341 404 N 50 62 157 157 P 421 463 616 680 R crs 318 318 318 318 S crs 356 356...

Page 22: ...100321 L100320 L100314 L100316 L100318 Gas Category II Heat input Gross kW 12 18 24 32 38 46 Gas consum rate Nat Gas G25 m h 1 33 1 99 2 66 3 55 4 21 5 10 Max Inlet pressure Nat Gas G25 mbar 50 Min In...

Page 23: ...2 L100321 L100320 L100314 L100316 L100318 Gas Category III Heat input Gross kW 12 18 24 32 38 46 Gas consum rate Propane G31 m h 0 45 0 68 0 90 1 21 1 43 1 73 Max Inlet pressure Propane G31 mbar 57 5...

Page 24: ...e Part No L104102 L104101 L104100 L104093 L104092 n a Burner Type Table 6 Heater Noise Data 12LR 18LR 24LR 32LR 38LR 46LR Noise level 3m below In Line BURNER db A tba tba 37 tba tba tba NR 2 tba tba 3...

Page 25: ...8 60 Noise level 3m below in acoustic enclosure db A 51 53 55 58 NR 2 45 47 49 52 Flue horizontal vertical 3m db A 69 72 75 77 NR 2 63 66 69 71 db A 56 57 58 58 NR 2 50 51 52 52 Flue horizontal vertic...

Page 26: ...Notes...

Page 27: ...Notes...

Page 28: ...hed off for periods in excess of one week it is highly recommended that both the gas and the electrical supplies are turned off 2 3 Routine Maintenance between Service Intervals After ensuring that th...

Reviews: