The following table gives you a survey of the parameters and their meaning 
 

Parameter 

Meaning 

ØRR 

Average heart rate over the whole measuring period of 5:35 min. 

SDRR 

Also called SDNN, standard deviation of the RR-intervals. The parameter 
represents the sympathetic and parasympathetic total activation over a 
measuring period of approx. 5 min. 

RMSSD 

The RMSSD (Root-Mean-Square of successive Differences) is currently the 
most popular and proven measure of the parasympathetic heart regulation. 

TP 

The TP (total power) parameter also represents the total status of the 
autonomic nervous system and highly correlates with the SDNN.  

VLF 

Very Low Frequency, is influenced by thermoregulatory and vasomotor 
processes. 

LF 

Low Frequency mainly describes the sympathetic influence on the heart 
rhythm regulation. 

HF 

High Frequency describes the parasympathetic influence on the regulation of 
the heart rhythm. 

LF/HF 

The LF/HF-ratio describes the sympathovagal balance of the autonomic 
nervous system and reveals shifts in the balance between the sympathetic 
and parasympathetic nervous system. . 

Ln(LF/HF) 

The natural logarithm of the previous LF/HF quotient. 

AR-Index 

Autonomic regulation index, i.e. health index of the autonomic nervous 
system. Developed by the ZNF research group. 

 

 

 

Summary of Contents for TechUnit

Page 1: ...USER S MANUAL ambiotex GmbH F rststr 49 72072 T bingen Germany T 07072 53 81 22 info ambiotex com www ambiotex com...

Page 2: ...d the U S A 4 Notices for Customers in Europe 4 Introduction 5 Intended purpose 5 Useful hints 5 Charging 5 The ambiotex Shirt 5 Washing instructions 5 The ambiotex TechUnit 6 First Steps 7 Using the...

Page 3: ...ll coming from the device unplug the USB charging cable or pull it off the shirt Do not use in presence of flammable gas Do not use electronic equipment in the presence if flammable gas as this could...

Page 4: ...radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio...

Page 5: ...uct and may therefore not be used for any diagnosis of disease Useful hints If you have not performed physical activity or strenuous sports for some time we recommend you to have your fitness checked...

Page 6: ...dicate the status of the TechUnit a No flashing TechUnit is turned off b Fast flashing green and red LEDs TechUnit is in advertising mode and ready to be paired with your smart phone c Green flashing...

Page 7: ...ont of you Switch on the TU by pressing the yellow button on the front side The LED should now be blinking c After a few seconds the TU should be visible as shown on figure 2 In case you don t see any...

Page 8: ...reen you can find the following control elements This button will lead you to the view of your personal activity history The first view is showing the target achievement of the daily goal you ve set F...

Page 9: ...u can modify and save your individual settings such as personal information You can also switch off the blinking LED light at the TechUnit If you intend to have your data saved long term you must star...

Page 10: ...metabolism The performance intensity of these units is less than 50 per cent of the individual anaerobic threshold 2 Basic endurance 1 GA1 Training within the compensation range serves as an active re...

Page 11: ...system in our body is responsible for recovery and regeneration If the sympathetic nervous system activates due to stress or over training the heart rate will not change while breathing and the heart...

Page 12: ...ress physical fitness The meaning of each axis can be found on the respective heading The graphic provides a quick overview of the current and former results 2 Heart rhythm diagram This image compares...

Page 13: ...power parameter also represents the total status of the autonomic nervous system and highly correlates with the SDNN VLF Very Low Frequency is influenced by thermoregulatory and vasomotor processes L...

Page 14: ...asily by switching the Bluetooth connection on your iPhone on and off again and starting the TU anew Problem The TU states that it is connected however it lost connection to the smart phone Solution I...

Page 15: ...otex GmbH Page 15 of 15 Contact Ambiotex GmbH F rststr 49 72072 T bingen Germany For further information please contact our support desk https ambiotex freshdesk com Or you can also get in touch with...

Reviews: