TECHNICAL  INFORMATION 

32 

 

PIN: 

0063CL1279

 

 

 
 
Inlet Pipe connection 

 

8mm Compression 

Appliance 

mass 

  5kg 

 
Electrical Supply 

 

230 V ~ 50Hz 0.085A 

Natural 

Gas Category 

I2H 

I2E 

I2E+ 

I2L 

Gas G20 

G20 

G20/G25 

G25 

Supply Pressure (mbar) 

20 

20 

20/25 

25 

Pilot Burner 

SIT 0.977.113 

Nominal Input (Gross kW) 

8.8 

8.8 

8.8/8.0 

8.0 

Gas Rate (max. m³/hr) 

0.838 0.838 

0.838/0.886

0.838 

Burner Pressure Mertik(Hot 
mbar) 12 

12 

12/16.3 

16.3 

Burner Pressure Seagas(Hot 
mbar) 10.8 

10.8 

10.8/14.7 

14.7 

Efficiency Class 

Nox Class 

Burner Injector 

650 

LPG 

Gas Category 

I3B/P 

I3+ 

I3B/P 

Gas G30/G31 

G30/G31

G31 

Supply Pressure (mbar) 

30 

28-30/37 

37 

Pilot Burner 

SIT 0.977.148 

Nominal Input (Gross kW) 

8.8 

Gas Rate (max. m³/hr) 

0.252 

0.331 

Burner Pressure Mertik(Hot 
mbar) 28.9 

36.8 

Burner Pressure Seagas(Hot 
mbar) 28.2 

35.5 

Efficiency Class 

Nox Class 

Burner Injector 

240 

 

 

 

 
 
 
 
 

 

Ambifuego 

Avda. Cañada del Cura, 29 

Poligono Industrial de Levante 

03187 Los Montesinos (Alicante) 

tel.: +34 96 672 1018 

[email protected]   www.ambifuego.net

 

KALIDO77 

 

 

USER, INSTALLATION AND SERVICING 

INSTRUCTIONS (GB & IE) 

 
 

Please read these instructions carefully before installation or use, and leave 

with the customer for storage is a safe place for future reference. 

 

This appliance has been designed and approved for use in other countries than shown on this 

cover. To install in other countries it is essential to obtain the manual in the local translation. 

Contact Ambifuego for further information. 

 

Summary of Contents for KALIDO77

Page 1: ...t Burner SIT 0 977 148 Nominal Input Gross kW 8 8 Gas Rate max m hr 0 252 0 331 Burner Pressure Mertik Hot mbar 28 9 36 8 Burner Pressure Seagas Hot mbar 28 2 35 5 Efficiency Class 2 Nox Class 5 Burne...

Page 2: ...f the fan is broken The electrical supply must be connected before the appliance is ignited If the power supply cord is damaged it must be replaced by the manufacturer it s service agents or similarly...

Page 3: ...r NO Norway I2H G20 20mbar PL Poland I2E G20 20mbar PT Portugal I2H G20 20mbar RO Romania I2H G20 20mbar SE Sweden I2H G20 20mbar SL Slovenia I2H G20 20mbar SK Slovakia I2H G20 20mbar TR Turkey I2H G2...

Page 4: ...s appliance is designed as a decorative heating device and consequently all body parts become very hot in use Except for the control knob and control access door which are designed to stay cool all ot...

Page 5: ...ish Development Department BS 1251 BS 5440 parts 1 2 BS 5871 part 2 BS 6461 part1 BS 6891 and BS 8303 In the Republic of Ireland the installation must also conform to the relevant standards particular...

Page 6: ...Fire BS5871 part 3 contains further details Battery type Remote Versions only Receiver 4x AA R6 size Transmitter PP3 Alkaline only INSTALLER INFORMATION 27 Servicing Instructions Ensure that the fire...

Page 7: ...tion until reaching stop depress and hold for five seconds only pilot gas flows Whilst still depressed turn further in an anti clockwise direction to activate the piezo If the pilot does not light rep...

Page 8: ...ring System This fire is fitted with a flue spillage safety device TTB If the fire shuts down during use for no apparent reason then several things may be suspected If a door or window has been opened...

Page 9: ...ccurs extinguish the appliance fully and re light following the procedures as previously described If the fire repeatedly shuts down by the monitoring system then a specialist engineer should be infor...

Page 10: ...and buttons of the receiver for ignition An acoustic signal indicates that the start sequence has begun The electronic system then checks that the main gas is flowing and ignites the main burner this...

Page 11: ...possible to turn the main burner all the way down so that it is effectively off leaving only the pilot ignited Extinguishing the Appliance Fully From any heat setting press the OFF button for a few s...

Page 12: ...ol To turn the appliance off using the manual override flip the ON OFF switch Please note The Manual Piezo Igniter is only available if purchased as an optional Extra however the manual ON OFF and Man...

Page 13: ...rol Igniting the Pilot Light Turn the Control knob slightly anti clockwise towards the ignition position until reaching stop depress and hold for five seconds only pilot gas flows Whilst still depress...

Page 14: ...e to Off position In the extent of a flue blockage or spillage the monitoring system will operate and turn off the fire If this occurs extinguish the appliance fully and re light following the procedu...

Page 15: ...re test point when the test is complete Site Requirements The fireplace opening should be inspected and repairs made where necessary It will usually be necessary to remove any chair brick that may be...

Page 16: ...y any amount of ventilation For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force INSTALLER INFORMATION 17 Installing the Appliance Notes Ensure that...