6
5.
Battery Status Control
LED / Status
Off
Constantly Lit
Blink
LED1: Power (blue)
No ext. battery
detected
Ext. battery present
Critical fault!*
LED2: Charge (red)
No charging of
int. battery
Charging in process
Hot-swap discharge
automatic switch-off
after 30s, rapid blink on
10s remaining
LED3: Ready (green)
No charging of
int. battery
Backup cell fully
charged
Charging fault, critical!*
* Blinking blue or red LED indicates a critical fault. Do not operate unit. Disconnect immediately from