Ambient Weather WS-1050 User Manual Download Page 14

 

Version 1.1  

 

 

©Copyright 2010, Ambient LLC. All Rights Reserved. 

 

 

 

Page 14 

5.4

 

  Alarm Mode 

 

Note: 

After  initially  pressing  the 

ALARM

  key,  the  display  will  show  the  current  high  and  low 

alarm values. The alarm value will be displayed only for those already activated,  otherwise, inactive 
alarms will show dashes (--). 
 
The  Alarm  mode  can  be  exited  at  any  time  by  either  pressing  the 

ALARM

  key  or  waiting  for  the 

10-second time-out to take effect. 
 

5.4.1

 

High Alarm Mode 

While  in  the Normal  mode,  press  the 

ALARM

  key  to  enter  the  High  Alarm  mode.  The 

HIAL

  icon 

will be displayed in the 

TIME

 section. 

 

1.

 

Time  of  Day  Alarm

.  Press the 

SET

  key  to  set  the  hour  of  day  alarm.  The  hour  will  begin 

flashing.    Press the 

+

 key (increase) or 

MIN/MAX

 key (decrease) to change the hour value.   

Press the 

SET

 key again to set the minute value.    The minute will begin flashing. Press the 

+

 key or 

MIN/MAX

 key to increase or decrease the minute value.   

 

Press the ALARM key to turn the alarm on or off (if the alarm is enabled, the alarm icon 

 

will be turned on). 
 

2.

 

Indoor  Humidity  High  Alarm

.  Press  the 

SET

  key  to  set  the  indoor  humidity  high  alarm. 

The  indoor  humidity  will  begin  flashing.    Press  the 

+

  key  (increase)  or 

MIN/MAX

  key 

(decrease) to change the indoor humidity alarm value. 
 

Press the ALARM key to turn the alarm on or off (if the alarm is enabled, the alarm icon 

 

will be turned on and the HI AL icon will be displayed). 
 

3.

 

Indoor  Temperature  High  Alarm

.  Press  the 

SET

  key  to  set  the  indoor  temperature  high 

alarm.  The  indoor  temperature  will  begin  flashing.    Press  the 

+

  key  (increase)  or 

MIN/MAX

 key (decrease) to change the indoor temperature alarm value. 

 

Press the ALARM key to turn the alarm on or off (if the alarm is enabled, the alarm icon 

 

will be turned on and the HI AL icon will be displayed). 
 

4.

 

Outdoor Humidity High Alarm

. Press the 

SET

 key to set the outdoor humidity high alarm. 

The  outdoor  humidity  will  begin  flashing.    Press  the 

+

  key  (increase)  or 

MIN/MAX

  key 

(decrease) to change the outdoor humidity alarm value. 
 

Press the ALARM key to turn the alarm on or off (if the alarm is enabled, the alarm icon 

 

will be turned on and the HI AL icon will be displayed). 
 

5.

 

Outdoor Temperature High Alarm

. Press the 

SET

 key to set the outdoor temperature high 

alarm.  The 

TEMP

  icon  will  be  displayed  and  the  outdoor  temperature  will  begin  flashing.   

Press the 

+

 key  (increase)  or 

MIN/MAX

 key  (decrease)  to change the outdoor  temperature 

alarm value. 
 

Press the ALARM key to turn the alarm on or off (if the alarm is enabled, the alarm icon 

 

Summary of Contents for WS-1050

Page 1: ...ay 10 5 Console Operation 10 5 1 Set Mode 10 5 1 1 Set Time 10 5 1 2 Set Date 11 5 1 3 Set Indoor Temperature and Outdoor Temperature Units 12 5 1 4 Set Barometric Pressure 12 5 1 5 Set Wind Units 12...

Page 2: ...user guide provides step by step instructions for installation operation and troubleshooting To download the latest manual and additional troubleshooting tips please visit http ambientweather wikispac...

Page 3: ...ansmitter radiation shield 1 Wind speed sensor 1 Rain gauge 1 Rain gauge mounting bracket 1 1 nut and bolt long 1 13 16 nut and bolt short 1 set screw long 1 3 8 set screw short Optional 1 Upper pole...

Page 4: ...Align the holes and fasten with long bolt and nut Tighten with precision screwdriver while securing the nut with pliers as shown in Front Back 1 Figure 1 front and back view Attach the small set scre...

Page 5: ...nting arm Figure 2 3 Connect the thermo hygrometer with short bolt and nut Tighten with precision screwdriver as shown in Figure 3 Slide the radiation shield over the thermo hygrometer after connectin...

Page 6: ...econds for each transmission update Note Do not install the batteries backwards You can permanently damage the thermo hygrometer Do not use rechargeable batteries Note We recommend installing Lithium...

Page 7: ...as shown in Figure 5 Slide the top weather station pole with the sensor array into the lower pole connected to your mounting pole when your station is finally mounted Figure 5 7 Install the solar shie...

Page 8: ...emperature and humidity low alarm and high alarm 14 Temperature display unit 15 General outdoor alarm icon 16 Weather forecast icon 17 Weather tendency indicator 18 Pressure unit relative or absolute...

Page 9: ...nstalling the sensor array 1 Verify proper operation of the rain gauge Tip the sensor array back and forth several times You should hear a clicking sound within the rain gauge Verify the rain reading...

Page 10: ...this into consideration when choosing console or mounting locations 6 Visit Ambient Weather Mounting Solutions for assistance and ideas for mounting your weather station http www ambientweather com a...

Page 11: ...ard Sydney 11 Magadan 12 IDLE International Date Line East NZST New Zealand Standard Wellington New Zealand 2 12 24 Hour Format Press the SET key to change the 12 24 hour format Press the key to alter...

Page 12: ...n 29 92 inHg are considered low pressure To determine the relative pressure for your location locate an official reporting station near you the internet is best source for real time barometer conditio...

Page 13: ...e Pressure Display Press the SET key to change the pressure display The pressure will begin flashing Press the key to alternate the display between absolute and relative pressure 5 2 3 Average Wind Sp...

Page 14: ...ng Press the key increase or MIN MAX key decrease to change the indoor humidity alarm value Press the ALARM key to turn the alarm on or off if the alarm is enabled the alarm icon will be turned on and...

Page 15: ...arm icon will be turned on and the HI AL icon will be displayed 9 Wind Speed High Alarm Press the SET key to set the wind speed high alarm The wind speed will begin flashing Press the key increase or...

Page 16: ...rm setting 7 Dew Point Low Alarm Reference Section 5 4 1 The low alarm is similar to the high alarm setting 8 Barometric Pressure Low Alarm Reference Section 5 4 1 The low alarm is similar to the high...

Page 17: ...key to reset the maximum indoor humidity to the current value date and time 2 Maximum Indoor Temperature Press the key to display the maximum indoor temperature with the associated time and date stam...

Page 18: ...ust to the current value date and time 5 5 2 Minimum Mode 1 Minimum Indoor Humidity Reference Section 5 5 1 The minimum setting is similar to the maximum setting 2 Minimum Indoor Temperature Reference...

Page 19: ...ndicator The weather tendency arrow is located between the weather icons to show the air pressure tendency and provide a forecast based on increasing or decreasing air pressure The arrow pointing to t...

Page 20: ...gnant 5 6 6 Pressure Graph Note The weather station bar graph flashes from left to right to prevent screen burn in This feature cannot be turned off The pressure graph displays the barometric pressure...

Page 21: ...or Temperature 40 to 149 F 2 F 0 1 F Indoor Humidity 10 to 99 4 1 Outdoor Humidity 10 to 99 4 1 Barometric Pressure 8 85 to 32 50 inHg 0 08 inHg within range of 27 13 to 32 50 inHg 0 01 inHg Rain 0 to...

Page 22: ...metal barriers example aluminum siding or multiple thick walls Temperature sensor reads too high in the day time In hot weather climates the rain guard and solar shield may not be effective enough Con...

Page 23: ...hours and varies from location to location The tendency is simply a tool for projecting weather conditions and is never to be relied upon as an accurate method to predict the weather 9 Accessories Th...

Page 24: ...of children No part of this manual may be reproduced without written authorization of Ambient LLC Ambient LLC WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES...

Page 25: ...ed by Ambient LLC The original dated bill of sale must be presented upon request as proof of purchase to Ambient LLC Your Ambient LLC warranty covers all defects in material and workmanship with the f...

Reviews: