Version 1.0
©Copyright 2017, Ambient LLC. All Rights Reserved.
Page 9
1.
If a specific channel is lost, press the
CH/+
button to display this channel, then Press and hold
the
CH/+
button for 3 seconds, and the remote search icon
will be constantly displayed
for up to 10 minutes. Once the signal is reacquired, the remote search icon
will turn off,
and the current values will be displayed.
2.
If new sensors are added, subtracted, or multiple sensor channels are lost, press the
CH/+
button until the indoor channel
is displayed. Press and hold the
CH/+
button for 3
seconds, and the remote search icon
will be constantly displayed for up to 10 minutes.
Once the signal is reacquired, the remote search icon
will turn off, and the current
values will be displayed.
5.7 Best Practices for Wireless Communication
Wireless communication is susceptible to interference, distance, walls and metal barriers. We
recommend the following best practices for trouble free wireless communication.
1.
Electro-Magnetic Interference (EMI)
. Keep the console several feet away from computer
monitors and TVs.
2.
Radio Frequency Interference (RFI).
If you have other 433 MHz devices and
communication is intermittent, try turning off these other devices for troubleshooting
purposes. You may need to relocate the transmitters or receivers to avoid intermittent
communication.
3.
Line of Sight Rating.
This device is rated at 300 feet line of sight (no interference, barriers or
walls) but typically you will get 100 feet maximum under most real-world installations,
which include passing through barriers or walls.
4.
Metal Barriers.
Radio frequency will not pass through metal barriers such as aluminum
siding. If you have metal siding, align the remote and console through a window to get a clear
line of sight.
The following is a table of reception loss vs. The transmission medium. Each “wall”or obstruction
decreases the transmission range by the factor shown below.
medium
RF Signal Strength Reduction
Glass (untreated)
5-15%
Plastics
10-15%
Wood
10-40%
Brick
10-40%
Concrete
40-80%
Metal
90-100%