50D0035 Rev 1 July 2002
Page 2 of 5
Ambient Technologies
A Division Of
Monessen Hearth Systems
L-Bracket
Slide Switch
Battery Door
WA
RNI
NG
Turn appliance OFF and allow to cool before installing or servicing. DO NOT connect
110-120 VAC wiring to the milli-volt gas control valve. The remote operator must be installed
exactly as outlined in these instructions. Read all instructions completely before attempting
installation. Follow instructions carefully during installation. Any modification of
components will void the warranty and may cause a fire hazard.
INSTALLATIONS
Remote Receiver:
The remote receiver may be wall mounted or installed in the appliance per the appliance homeowner’s manual.
Refer to the Homeowner’s Manual for special installation instructions.
If wall mounted, the remote receiver
must be installed in a junction box with cover plate provided. Failure to follow the installation instructions found in
the appropriate Homeowner’s Manual will void the warranty and may cause a fire hazard.
Installing Batteries:
The remote receiver uses four (4) “AA”- size batteries. To install batteries,
1.
Remove the slide switch by gently pulling straight out.
2.
Use your thumb and index finger to gently pull down the L-bracket.
3.
Open the battery door by pressing the two tabs located on the door.
4.
Install the batteries as indicated in the receiver cover.
5.
Close the battery door until the door tab snaps in place.
6.
To install the receiver into a wall junction box, install the receiver with
the screws provided .
7.
If you decided to install the receiver into the appliance, reinstall the L-
bracket.
8.
Gently, install the slide switch back to the receiver stem.
9.
The batteries should be replaced at least once every 6 months or when
the battery indicator flashes.
Installing Wire:
This system comes with an 18 inch pre-assembled wire assembly. Insert the white terminal to the back of the
receiver. The terminal wire block can only be installed one way. Do not force the terminal plug onto the receiver.
Follow the homeowner’s manual for connecting the two (2) 1/4” female spade terminals to the millivolt valve.
For applications longer than 18 inches, use 18 gauge wire, 105ºC rated, with no splices. Connect to the two (2) 1/4“
female spade wiring terminals. Wire can be no longer than 20 feet.