Amber Wireless AMB8466-M-GMM Quick Start Manual Download Page 2

 

 

 

Quick-start AMB8466-M-GMM Configurator 

2 / 7 

Stand: 18.12.2013 

 

Figure 1: Start-screen 

2.1

 

Configuration of the AMB8465-M USB stick 

Select the COM-port connection as supplied by the AMB8465-M USB stick. 

The configuration of the AMB8465-M USB stick to be communicated with follows clicking on the 
“open” button. The Configuration program tries to connect to the USB stick via the selected 
COM-port and if necessary performs a reconfiguration of the parameters. 

 

When using the AMB8465-M stick for other programs, please ensure that these 
programs use the following COM-port settings: 115200 Baud 8n1. The default 
shipment state of the AMB8465-M is set to 9600 Baud 8n1. 

In the event of a 

successful reconfiguration the status message “AMB8465-M Configuration 

successful

” will be displayed in the message window of the configuration program. 

After opening the COM-port the following buttons are activated: 

  Read Configuration 

  Write Configuration 

  Firmware Update  

  Close (COM-port) 

Summary of Contents for AMB8466-M-GMM

Page 1: ...ion devicetype manufacturer and or the used m bus baudrate 300 2400 or 9600 is not known 2 Requirements The PC or laptop is connected via a USB stick AMB8465 M The software has been designed for the f...

Page 2: ...d COM port and if necessary performs a reconfiguration of the parameters When using the AMB8465 M stick for other programs please ensure that these programs use the following COM port settings 115200...

Page 3: ...button again the POWER and ERROR LED s blink simultaneously Now after releasing the button the activated software immediately starts to read the configuration Alternatively you may also disconnect th...

Page 4: ...2 5 Adapt configuration After confirmation of the success message the read out data is displayed The display is split into two tabs namely configuration of the user settings and enhanced user settings...

Page 5: ...n from wildcards and to rather perform a detailed configuration The MeterID refers to the number of the meter the respective wildcard would be FFFFFFFF The Manufacturer Token is a manufacturer identif...

Page 6: ...diness of configuration A write procedure requires more commands then the read out procedure Similar to that of the read procedure the success of a write procedure is also displayed by a respective me...

Page 7: ...OK button the readiness for configuration has to be established Subsequently after the verification of the compatibility of the firmware to the configured device the firmware is transferred to the de...

Reviews: