2. 

Electrical characteristics 

CHARACTERISTIC DESCRIPTION 

VALUE 

MIN. 

TYP. 

MAX. 

UNIT 

SUPPLY VOLTAGE 

Supply Voltage (Recommended Operating 
Conditions) 

+10 

 

+30 

DIGITAL OUTPUT (OPEN DRAINGRADE) 

Drain current (Digital Output OFF) 

 

 

120 

µA 

Drain current (Digital Output ON, 
Recommended Operating Conditions) 

 

0.1 

0.5 

Static Drain-Source resistance (Digital Output 
ON) 

 

400 

600 

mΩ 

DIGITAL INPUT  

Input resistance (DIN1) 

47 

 

 

kΩ 

Input resistance (DIN2) 

51.7 

 

 

kΩ 

Input resistance (DIN3) 

150 

 

 

kΩ 

Input voltage (Recommended Operating 
Conditions) 

 

Supply 
voltage 

Input Voltage threshold (DIN1) 

 

7.5 

 

Input Voltage threshold (DIN2) 

 

2.5 

 

Input Voltage threshold (DIN3) 

 

2.5 

 

ANALOG INPUT  

Input voltage (Recommended Operating 
Conditions), Range 1 

 

+10 

Input resistance, Range 1 

 

38.45 

 

kΩ 

Measurement error on 12V, Range 1 

 

0.9 

 

Additional error on 12 V, Range 1 

 

108 

 

mV 

Measurement error on 30 V, Range 1 

 

0.33 

 

Additional error on 30 V, Range 1 

 

88 

 

mV 

Input Voltage (Recommended Operating 
Conditions), Range 2 

 

+30 

Input resistance, Range 2 

 

150 

 

kΩ 

Measurement error on 12 V, Range 2 

 

0.9 

 

Additional error on 12 V, Range 2 

 

108 

 

mV 

Measurement error on 30 V, Range 2 

 

0.33 

 

Additional error on 30 V, Range 2 

 

88 

 

mV 

OUTPUT SUPPLY VOLTAGE 1-WIRE 

Supply voltage 

+4.5 

 

+4.7 

Output inner resistance 

 

 

Ω 

Output current (Uout > 3.0 V) 

 

30 

 

mA 

Short circuit current (Uout = 0) 

 

75 

 

mA 

 

Summary of Contents for AMB375

Page 1: ......

Page 2: ...e Station Class B Data support SMS text data POWER Input voltage range 10 30 V DC with overvoltage protection Back up battery 170 mAh Li Ion battery 3 7 V 0 63 Wh Internal fuse 3 A 125 V Power consump...

Page 3: ...e Manual Geo fence Trip Sleep modes GPS Sleep Online Deep Sleep Deep Sleep Ultra Deep Sleep SMS Configuration Events DOUT control Debug GPRS commands Configuration DOUT control Debug Time Synchronizat...

Page 4: ...Bluetooth fuel sensor Analog fuel sensor RFID reader Wired temperature sensor ACCESSORIES Bluetooth and analog fuel sensor RFID reader Temperature sensor...

Page 5: ...DIN1 7 5 V Input Voltage threshold DIN2 2 5 V Input Voltage threshold DIN3 2 5 V ANALOG INPUT Input voltage Recommended Operating Conditions Range 1 0 10 V Input resistance Range 1 38 45 k Measuremen...

Page 6: ...Digital input channel 3 4 DIN 2 Digital input channel 2 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Ground pin 10 30 V DC 8 DOUT 1 Digital output channel 1 Open collector output M...

Page 7: ...these accessories settings in our amber connect fleet management platform Fleet Portal Settings Vehicle Safety Device Input Configuration This setting available Only to specific device models that sup...

Page 8: ...model this may happen in 5 to 30 minutes period b When the module is connected measure the voltage again to make sure it did not decrease c It is recommended to connect to the main power cable in the...

Page 9: ...the device in an impact proof package Before usage the device should be placed so that its LED indicators are visible They show the status of device operation When connecting the 2x6 connector wires t...

Page 10: ...declare under our sole responsibility that the above described product is in conformity with the relevant Community harmonization European Directive 2014 53 EU RED Installation and or handling during...

Reviews: