Supply Voltage
Supply Voltage (Recommended
Operating Conditions)
+10
+30
V
Digital Output (Open Drain grade)
Drain current
(Digital Output OFF)
120
μA
Drain current (Digital Output
ON, Recommended Operating
Conditions)
0.5
A
Static Drain-Source resistance (Digital
Output ON)
400
300
mΩ
Digital Input
Input resistance (DIN1)
15
kΩ
Input resistance (DIN2)
15
kΩ
Input resistance (DIN3)
15
kΩ
Input resistance (DIN4)
15
Input voltage (Recommended Operating
Conditions)
0
Supply
voltage
V
Input Voltage threshold (DIN1, DIN2,
DIN3,DIN4)
7.5
V
Analog Input
Input voltage (Recommended Operating
Conditions), Range 1
0
+10
V
Input resistance
120
kΩ
Input Voltage (Recommended Operating
Conditions), Range 2
0
+30
V
Input resistance
147
kΩ
1-Wire
Supply voltage
+3.3
+3.9
V
Output inner resistance
7
Ω
Output current (U
out
> 3.0 V)
30
mA
Short circuit current (U
out
= 0)
75
mA
CAN Interface
Internal terminal resistors CAN bus
120
Ω
Differential input resistance
19
30
52
kΩ
Recessive output voltage
2
2.5
3
V
Differential output voltage
0.5
0.7
0.9
V
Common mode input voltage
-30
30
V
Safety information
This message contains information on how to operate AGT400-LA safely. By following these
requirements and recommendations, you will avoid dangerous situations. You must read
these instructions carefully and follow them strictly before operating the device!
• The device uses SELV limited power source. The nominal voltage is +12 V DC. The
allowed voltage range is +10...+30 V DC.
• To avoid mechanical damage, it is advised to transport the device in an impact-proof
package. Before usage, the device should be placed so that its LED indicators are
visible. They show the status of device operation.