background image

 

Supply Voltage  

Supply Voltage (Recommended  
Operating Conditions)  

+10  

 

+30  

V  

Digital Output (Open Drain grade)  

Drain current  
(Digital Output OFF)  

 

 

 

 
 

120  

μA  

Drain current (Digital Output  
ON, Recommended Operating 
Conditions)  

 
 
 

 

0.5  

A  

Static Drain-Source resistance (Digital 
Output ON)  

 

400  

300  

mΩ  

Digital Input  

Input resistance (DIN1)  

15 

 

 

kΩ  

Input resistance (DIN2)  

15 

 

 

kΩ  

Input resistance (DIN3)  

15 

 

 

kΩ  

Input resistance (DIN4) 

15 

 

 

 

Input voltage (Recommended Operating 
Conditions)  

0  

 

Supply 
voltage  

V  

Input Voltage threshold (DIN1, DIN2, 
DIN3,DIN4) 

 

7.5  

 

V  

 

Analog Input  

Input voltage (Recommended Operating 
Conditions), Range 1  

0  

 

+10  

V  

Input resistance  

 

120 

 

kΩ  

Input Voltage (Recommended Operating 
Conditions), Range 2  

0  

 

+30  

V  

Input resistance  

 

147 

 

kΩ  

1-Wire  

Supply voltage  

+3.3  

 

+3.9  

V  

Output inner resistance  

 

7  

 

Ω  

Output current (U

out

 > 3.0 V)  

 

30  

 

mA  

Short circuit current (U

out

 = 0)  

 

75  

 

mA  

 

CAN Interface  

Internal terminal resistors CAN bus  

 

120 

 

Ω  

Differential input resistance  

19  

30  

52  

kΩ  

Recessive output voltage  

2  

2.5  

3  

V  

Differential output voltage 

0.5  

0.7  

0.9  

V  

Common mode input voltage  

-30  

 

30  

V  

 

  Safety information  

 

         

This message contains information on how to operate AGT400-LA safely. By following these    

 

requirements and recommendations, you will avoid dangerous situations. You must read  

 

 

these instructions carefully and follow them strictly before operating the device!  

 

•  The device uses SELV limited power source. The nominal voltage is +12 V DC. The  

 

 

allowed voltage range is +10...+30 V DC.  

•  To avoid mechanical damage, it is advised to transport the device in an impact-proof  

 

 

package. Before usage, the device should be placed so that its LED indicators are  

 

 

visible. They show the status of device operation.  

Summary of Contents for AGT400-la

Page 1: ......

Page 2: ...devices 4 DIN4 Digital input channel 1 5 DIN2 Digital input channel 2 6 CAN 2L SAE J1939 CAN interface Low channel 2 7 AIN2 Analog input channel 2 Input range 0 30V 0 10V DC 8 DOUT3 Digital output Op...

Page 3: ...achograph Vehicle Data transfer Wiring scheme AGT400 LA Wiring scheme Set up your device How to insert Micro SIM card and connect the battery 1 Unscrew 4 screws counter clockwise that are located on t...

Page 4: ...wires or non moving parts Try to avoid heat emitting and moving objects near the wires 3 The connections should not be seen very clearly If factory isolation was removed while connecting wires it sho...

Page 5: ...be chosen Connecting ground wire 1 Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame 2 If the wire is fixed with the bolt the loop must be connected to the end...

Page 6: ...WCDMA B1 B2 B5 B8 4G bands EG91 EX LTE FDD B1 B3 B7 B8 B20 B28 Data transfer LTE LTE FDD Max 10Mbps DL Max 5Mbps UL UMTS WCDMA Max 384Kbps DL Max 384Kbps UL Data support SMS text data Power Input vol...

Page 7: ...b FOTA Amber Configurator USB SMS Configuration Events DOUT control Debug GPRS commands Configuration DOUT control Time Synchronization GPS NITZ NTP Fuel monitoring LLS Analog LV CAN ALL CAN CAN FMS R...

Page 8: ...ge 3 3 3 9 V Output inner resistance 7 Output current Uout 3 0 V 30 mA Short circuit current Uout 0 75 mA CAN Interface Internal terminal resistors CAN bus 120 Differential input resistance 19 30 52 k...

Page 9: ...ice before unplugging the power supply All wireless data transferring devices produce interference that may affect other devices which are placed nearby The device must be connected only by qualified...

Page 10: ...ll batteries carry a reduced 6 month warranty period If a product should fail within this specific warranty time the product can be Repaired Replaced with a new product Replaced with an equivalent rep...