INSTALLATION

INSTRUCTIONS

CAUTION: 

DO NOT TAKE OFF THE PROTECTIVE P.V.C. TAPE BEFORE INSTALLING TOWEL WARMER TO 
AVOID SCRATCHING, MARKING OR GRAZING THE SURFACE. 

Setscrew

Threaded 

Long Tube

• 

Take the threaded long tube (4) and screw it 
down completely to the threaded wall-support (2) 
; to adjust the distance from wall unscrew tube 

Brick Wall

Plastic 

Anchor

Brick wall:

• 

Drill the holes in the wall ø6 mm ( 1/4 inches) 
and put the plastic anchor (1) into the wall;

Drywall:

• 

Leave out the plastic anchor (1) and proceed 
with step 2

STEP 1

STEP 3

STEP 5

STEP 6

STEP 2

Drywall

Anchor 

Screw

Drywall:

• 

Fasteners should be fixed to studs or structural 
members behind the drywall

• 

If not possible on both sides, toggle bolts can 
be used on one side.

• 

Proceed laying the threaded wall-support (2) 
on the hole and fasten it with the anchor bolt 
screw: repeat this procedure also for the other 
points marked on the wall

Fixing Screw

Bushing

BACK SIDE OF 

TOWEL WARMER

• 

Laythe bushing (7) on the holes of the towel warmer. 
And fasten it with the fixing screw (6); 

• 

Repeat this procedure also for the other connecting 
holes of the towel warmer.

• 

Install the towel warmer in the four connections as 
shown in drawing. Technical Drawings can be found 
on our website www.Ambaproducts.com

Threaded Wall-

Support

STEP 4

INSTALL DIGITAL HEAT CONTROLLER OR 
SWITCH — SEE PAGES 6 OR 7.

REMOVE THE PROTECTIVE P.V.C. TAPE BEFORE 

SWITCHING THE TOWEL WARMER ON

• 

For each leg fasten the Setscrew and place the 
cover onto the bracket

Summary of Contents for VEGA V2322

Page 1: ...e 404 350 9738 Fax 404 355 0166 www ambaproducts com 3165407 IP 54 SKU Width HEIGHT Power Amps BTU V2322 22 7 8 22 180 watts 1 4 546 V2342 22 7 8 42 1 2 296 watts 2 6 1009 V2352 22 7 8 51 1 2 370 watt...

Page 2: ...se of damaged wire or plug in case of malfunction drop or other kind of circumstance that may require adjustments or repair contact Amba Products We recommend the p V C Protective tape is left in plac...

Page 3: ...ety Surface temperatures of appliances during normal operations are maintained below the temperature of 60 65 c 140 149 f without towels and 90 c 194 f with towels as required by following standards F...

Page 4: ...ural members behind the drywall If not possible on both sides toggle bolts can be used on one side Proceed laying the threaded wall support 2 on the hole and fasten it with the anchor bolt screw repea...

Page 5: ...r use only Ensure that room trip switch is off before any operation Wrong wiring connection to the power source will cause sparks and the burning damage to the digital heat controller carefully consul...

Page 6: ...C Output cable D Towel Warmer cable E Ground faston POWER REGULATOR 1 Connect T1 A T2 B T3 D to faston T E 2 Connect L 1 A L2 B 3 Connect N 1 A N2 8 4 Connect N3 0 N4 C 5 Connect L3 0 L4 C Level Setti...

Page 7: ...the fastenings of the towel warmer s cable to the other section See the example below Connect one cable to the left section Electrical bridge 1 1 2 2 Connect the other cable to the right Electrical b...