9.1.8 Checking the oil level in the angular gearbox
INTERVAL
After initial operation
Every 50 operating hours
or
weekly
1.
Park the implement on a horizontal surface.
2.
Remove the oil dipstick
1
.
3.
Read the oil level from the dipstick.
4.
If the oil level is not between the markings on
the dipstick,
Refill the oil through the opening of the oil
dipstick according to the specification
2
and the
technical data.
5.
When the oil level is visible between the
markings on the dipstick,
install the oil dipstick with a new sealing ring.
6.
install the oil dipstick with a new sealing ring.
CMS-I-00003040
9.1.9 Checking the oil level in the spur gear trough
INTERVAL
After initial operation
Every 50 operating hours
or
weekly
IMPORTANT
Damage due to impurities in the spur gear
trough
Clean the implement before performing