AMAV MACRO80P Installation And Operation Manual Download Page 5

R E A R   PA N E L

PA G E   4

M I C R O 2 0 / M A C R O 8 0 P   I N S TA L L AT I O N   &   O P E R AT I O N   M A N U A L

 

MASTER LEVEL CONTROL

This control will set the output 
volume for all speakers, including the 
level of the sub and the level of all 
satellite speakers.

 

SATELLITE LEVEL CONTROL

This control will set the output volume 
for the satellite speakers. There is 
a separate level control for each 
satellite output (A, B, C and D) allowing 
individual level adjustment for each 
speaker, within the overall volume 
level set by the Master level control.

 
 INPUT

The MACRO80P can accept both 
balanced and unbalanced stereo line 
level inputs.

  NOTE: The sub is fed with a 

 

mono summed signal from both 

 

the left and right inputs. The 

 

left signal feeds the A and C 

 

satellite speaker outputs, whilst 

 

the right signal feeds the B and 

 

D satellite speaker outputs.

 STEREO/MONO 

SWITCH

This switch can be used to defeat 
the stereo capabilities of the speaker 
system. When set to “STEREO”, the 
left signal will feed the Sub A and C 
speakers whilst the right signal will 
feed the Sub B and D speakers. When 
set to “MONO”, both the left and right 
signals are mono summed internally, 
allowing signal on either the left or 
right inputs to feed all speakers.

 SPEAKER 

OUTPUTS

These outputs are used to connect 
the MICRO20 satellite speakers. This 
signal is electronically high pass fi l-
tered at 80Hz. There are four satellite 
speaker outputs.

 POWER 

SWITCH

This switches the mains power “on” 
for the internal amplifi er

 POWER 

INDICATOR

This LED illuminates to indicator that 
power is available and the Macro80P 
is powered on

 POWER 

INLET

Standard IEC 230V/10A mains 
connection. The Macro80P draws a 
maximum current of 1.2 amps. Only 
a 250V/2A slow blow fuse should 
be used.

 

WMVC CONTROL PORT

Standard RJ45 connector for the 
WMVC remote wall mount volume 
controller. Connection between the 
MACRO80P and WMVC is via a 
standard RJ45 CAT5 cable (straight 
through, pin to pin).

 BASS 

CONTROL

This is a shelf EQ that will cut or 
boost the bass frequencies by up to 
+/-10dB. This low shelf set to 100Hz.

 TREBLE 

CONTROL

This is a shelf EQ that will cut or 
boost the treble frequencies by up to 
+/-10dB. This high shelf set to 10kHz.

 
 VOLUME 

CONTROL

This control will set the output 
volume for the speaker system, 
affecting both sub and satellite 
speaker level. This level control 
is effected by the SATELLITE LEVEL 
CONTROL (2) and MASTER LEVEL 
CONTROL (1) on the MACRO80P. 

1

4

2

3

5

6

7

8

9

10

11

12

2

1

5

3

4

6
7

8

9

10

11

12

Summary of Contents for MACRO80P

Page 1: ...ustralian Monitor 1 Clyde Street Silverwater NSW 2128 Australia 61 2 9647 1411 www australianmonitor com au SERVICE INFORMATION MACRO80P POWERED LOUDSPEAKER CONTENTS OPERATION MANUAL SCHEMATIC DIAGRAM...

Page 2: ...MICRO20 MACRO80P ACTIVE TWO WAY STEREO SPEAKER SYSTEM INSTALLATION AND OPERATION MANUAL...

Page 3: ...producing devices 13 Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug weath...

Page 4: ...3 REAR PANEL 4 MOUNTING DETAIL 5 SPECIFICATIONS 6 INTRODUCTION AND CONTENTS PAGE 3 MICRO20 MACRO80P INSTALLATION OPERATION MANUAL AUS EUR USA REV A Oct 2007 This symbol is intended to alert the user t...

Page 5: ...llowing signal on either the left or right inputs to feed all speakers SPEAKER OUTPUTS These outputs are used to connect the MICRO20 satellite speakers This signal is electronically high pass fil tere...

Page 6: ...MOUNTING DETAIL PAGE 5 MICRO20 MACRO80P INSTALLATION OPERATION MANUAL MICRO20 BRACKET MOUNTING DETAIL WMVC MOUNTING DETAIL...

Page 7: ...r 75mm TWEETER Diameter 25mm IMPEDANCE 8 ohm POWER RMS 30W Program 60W Peak 120W SENSITIVITY 1W 1m 84dB FREQUENCY RESPONSE 3dB 140Hz 30kHz DISPERSION H X V 120 x 90 DIMENSIONS H X W X D 150mm x 90mm x...

Page 8: ...hms 1 THD RMS 25W 2 ohms 1 THD RMS Not Recommended SUB BANDPASS 40Hz 175Hz SATELLITE BANDPASS 80Hz 30kHz INPUT SENSITIVITY 85mV CURRENT DRAW 1 2A max FUSE RATING 250V 2A SB DIMENSIONS H X W X D 405mm...

Page 9: ...31 Walsh Street Thebarton SA 5031 PO Box 157 Hindmarsh SA 5007 Phone 08 8352 4444 Fax 08 8352 4488 Email sa audiotelex com au PERTH WA SALES 3 11 Howe Street Osborne Park WA 6017 PO Box 1281 Osborne P...

Page 10: ...C 100E R47C 220E R45C 2K2 R46C 100K R50A 2K2 R53A 1M R52A 47K R51A 47K R55A 100E R54A 1M R57A 100K R56A 10K R58A 10k R48A 2K2 R49A 100E R47A 220E R45A 2K2 R46A 100K R52B 47K R50D 2K2 R53D 1M R52D 47K...

Page 11: ...0E 1 4W R8D 10E 1W R5D 4 7Ohm R3D 68K R2D 22K R1B 22K R13 R17 10K R16 4K7 R14 10K R12 10K R11 22K R15 10K R4C 10E 1 4W R8C 10E 1W R5C 4 7Ohm 1W R3C 68K R2C 22K R1C 22K R4A 10E 1 4W R8A 4 7Ohm 1W R3A 6...

Page 12: ...F C45 1KP Q1 C3198Yx2 C40 100uF 25Vx2 C41 Q2 Q3 A1266Y D3 1N4148 Q4 C3198Y C48 0 1uF C49 47uF 25V C50 0 1uF C46 47uF C4A 1uF C47 47uF 25V R38 3K3 R39 10K R40 10K R42 22K R41 10K R46 10K R51 100K R45 1...

Page 13: ...C8 10u 25V C7 10u 25V 1 2 3 U1 7812 2 3 1 U2 7912 D5 1N4007 C6 C5 6800u 50V C4 C3 C2 C1 1uF X4 BR1 CN3 CN2 CN1 TO PN3 OF POW AMP PCB TO SUB WOOFER PCB CN6 V V GND TO POW AMP PCB 12V G A 12V G B FROM...

Reviews: