6
Troubleshooting
Symptom
Solution
No operation/ no fan.
Check for safety cut-off operation.
No fire effect light.
Check the bulb by replacement.
Replacing the Lamp
Caution: The lamps must be in place.
·
Warning
-Always disconnect from the power supply before removing bulb.
·
Warning
-The bulbs reach high temperatures during operation. Allow the bulbs to cool down
after switching off the appliance before changing lamps.
·
Note
: Two people will be required for this process.
·
It is recommended that the fire is carefully removed from the wall and laid on its back
in order to replace the lamp.
·
Gently slide the front glass panel towards the top of the fire and remove. Store the
glass safely out of the way whilst the bulb is replaced so that it does not get damaged.
·
At the bottom of fire, there is a lamp cover fixed by eight Philip's head screws, remove the
eight screws and lift off the lamp cover-see Fig.5.
·
For access to the bottom bulbs, carefully slide the flexible rotisserie to one side ensuring that
the rubber grommet is not lost-see Fig.6
·
Remove the defective bulb by unscrewing it.
·
Replace with a 40W E12 SES Clear Candle bulb, rotating it. Take care not to over-tighten the
bulb.
·
Refit the rotisserie making sure that the rubber grommet is carefully pushed into the slotted
hole on the axial bracket.
·
Lift the fire back onto the wall and replace the glass front by lifting onto the lugs either side of
the fire.
Cleaning
·
Warning
-Always disconnect from the power supply before cleaning heater
·
For general cleaning use a soft clean duster-never use abrasive cleaners. The glass viewing
screen should be cleaned carefully with a soft cloth. DO NOT use proprietary glass cleaners.
Technical Specification
·
Supply: 100-120V~ 60Hz
·
Rated power:1500W
·
Lighting: 40W E12 SES Clear Candle bulb
Summary of Contents for WM-3522CF
Page 2: ...2...