Display (continued)
Resolution.......................
240 x 320 Pixels.
Color ...............................
65 K Color Screen.
Back-lighting ...................
Permanently on.
Status LED
Power On........................
Continuous Red.
Upgrade Mode ................
Flashing Red.
Incoming RS485 Data ............
Flashing Green LED.
Outgoing RS485 Data ............
Flashing Red LED.
Digital Inputs (1-4) ..................
Continuous Green on detected contact
closure.
Relays (1 and 2) .....................
Continuous Red on activation of the Relay.
Locked ...................................
Continuous Green when locked.
Unlocked ................................
Continuous Green when unlocked.
Enet Act (Ethernet Activity) ....
Flashing Red LED.
Enet Spd (Ethernet Speed) ....
Continuous Red for 100 Mbps (Default)
Off for 10 Mbps.
Enet Lnk (Ethernet Link) ........
Continuous Red on connection to network.
INSTALLATION INFORMATION
Accessories
CAUTION:
The Nexus Lite Controller needs a standard Ethernet cable to
connect to a PC. We do NOT however supply this cable with the
Controller’s accessories.
Find the following when unpacking the Amano Nexus Lite Controller:
Either an Amano Nexus Lite Controller with Web Interface (ISC920) supplied in a
Black ABS Plastic housing. The housing consists of a Front Cover Assembly and
a Mounting Plate. The Front Cover and Mounting Plate are held together with two
Combi Screws (M4 x 10 mm) at the bottom of the housing.
Or, an Amano Nexus Lite Controller with Touch Screen (ISC921) supplied in a
Black ABS Plastic housing. The housing consists of a Front Cover Assembly and
a Mounting Plate. The Front Cover and Mounting Plate are held together with two
Combi Screws (M4 x 10 mm) at the bottom of the housing.
CAUTION:
DO NOT use the Metal-oxide Varistors (25 Vrms, 500 A, 77 V max
clamping) with mains power applications.
Three Metal-Oxide Varistors, 25 Vrms, 500 A, 77 V max clamping.
A 3 V, CR2032, Lithium cell Battery.
NOTE:
The 3 V, CR2032 Lithium cell Battery is partially installed in all models of the
Nexus Lite Controller.
An extra Fixed Address Label.
Summary of Contents for Nexus Lite ISC920-0-0-AC Series
Page 14: ...ISC304 0 0 AC 04 November 2010 Page 14 Figure 7 Motor Lock Connection Details ...
Page 15: ...ISC304 0 0 AC 04 November 2010 Page 15 Figure 8 Solenoid Lock Connection Details ...
Page 18: ...ISC304 0 0 AC 04 November 2010 Page 18 Fixed Address Label Unique Location Description ...
Page 19: ...ISC304 0 0 AC 04 November 2010 Page 19 Fixed Address Label Unique Location Description ...
Page 20: ...ISC304 0 0 AC 04 November 2010 Page 20 Fixed Address Label Unique Location Description ...
Page 22: ...ISC304 0 0 AC 04 November 2010 Page 22 USER NOTES ...
Page 23: ...ISC304 0 0 AC 04 November 2010 Page 23 USER NOTES ...
Page 51: ...ISC305 0 0 AC 02 October 2010 Page 27 User Notes ...