background image

 

4

 

   

 

Block Sensor Test 

Lefthand Figure shows the number of blocks read (26), while the righthand figure shows the maximum 
(40) and minimum (34) value for block darkness. 

 

 

Timing Sensor Test 

 
This test verifies the functioning of the Timing Sensor which monitors the motion of the Time Card in 
the clock. 

Note:

 The Card Sensor must be functioning in order to run this test.  

 

1.  Enter the Program Mode. Press the 

Function

 key until menu 8 

appears.  

2. Press 

the 

Change

 key 15 times until menu item 16 is displayed. 

3. Press 

the 

Enter

 key to start the test.  

4.  Insert a Time Card into the throat and gently move it up and down. 

The number on the right side of the display will count from “0001” through 
“9999” and then start over as the card is moved. 

5.  Remove the card when finished and exit Program Mode. 

 

Reviews: