![Amano 07076B Operator'S Manual Download Page 10](http://html1.mh-extra.com/html/amano/07076b/07076b_operators-manual_2918211010.webp)
10
Problem
Possible Cause
Action
Motor will not start.
No Power.
Check power supply and connection.
Interlock not depressed.
Depress interlock before activating control lever.
Defective switch / bad connection.
Contact an authorized American Sanders Dealer.
Motor fails to start /
runs sluggish.
Low voltage from excessive length or
undersized extension cord.
Use a 12 Ga. extension cord, not to exceed 50 feet (15m) length.
Defective start capacitor.
Contact an authorized American Sanders Dealer.
Defective start switch.
Contact an authorized American Sanders Dealer.
Defective run capacitor.
Contact an authorized American Sanders Dealer.
Defective motor.
Contact an authorized American Sanders Dealer.
Fuse / circuit breaker
repeatedly trips.
Low voltage.
Eliminate extension cord.
Locate power source closer to work site.
Have voltage checked by a qualified electrician.
Bad connection.
Contact an authorized American Sanders Dealer.
Defective motor.
Contact an authorized American Sanders Dealer.
Troubleshooting
Section - A