20
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
Illustration Component
Testing
Results
Thermal cutout
Disconnect all wires from TCO.
Measure resistance across terminals.
Cavity TCO .............................................
Magnetron TCO ......................................
Closed at 32
q
F (0
q
C) and
Opens at 230
q
F (110
q
C)
Closed at 140
q
F (60
q
C) and
Opens at 320
q
F (160
q
C)
Diode
Discharge Capacitor
Remove diode lead from capacitor and
connect ohmmeter.
Reverse leads for second test.
Infinite resistance should be
measured in one direction and 50K
:
or more in the opposite direction.
NOTE:
Ohmmeter must contain a
battery of 6 volts minimum.
Capacitor
Discharge Capacitor
Remove wires from capacitor terminals
and connect ohmmeter, set on highest
resistance scale to terminals.
Also check between each terminal and
capacitor case.
Between Terminals: Meter should
momentarily deflect towards zero
then return to over 5 M
:
. If no
deflection occurs, or if continuous
deflection occurs, replace capacitor.
Terminal to Case: Infinite resistance
Magnetron
Discharge Capacitor
Remove wires from magnetron and
connect ohmmeter to terminals. Also
check between each terminal and
ground.
Between Terminals: Less than 1
:
Each terminal to ground measures
Infinite resistance.
Note:
This test is not conclusive. If
oven does not heat and all other
components test good replace the
magnetron and retest.
Blower motor
Remove all wires from motor.
Measure resistance across coil ..............
Approximately 28 – 35
:
Stirrer motor
Remove all wires from motor.
Measure resistance across terminals .....
Approximately 12 – 14 K
:
Filament
Secondary
Primary
Transformer
Discharge Capacitor
Remove all wires from terminals.
Measure resistance from:
Primary ..................................................
Filament.................................................
Secondary to Ground screw on
transformer stack...................................
Less than <1
:
Less than <1
:
Approximately 90-100
:
Noise filter board
Power In terminals ..................................
Power Out terminals ...............................
120 VAC (RFS12)
120 VAC (RFS12)
If no power in, check power outlet.
If no power out, check fuses.
Circuit Protector
Measure resistance across terminals .....
Between Terminals: Less than 1
:
Power In terminals ..................................
Power Out terminals ...............................
240 VAC (RFS18)
240 VAC (RFS18)
Component Testing Procedures
2011 RFS Training Manual.indd 20
10/3/2011 8:36:45 AM
Summary of Contents for RFS Models
Page 3: ...1 Important Safety Information 1 2011 RFS Training Manual indd 1 10 3 2011 8 36 35 AM ...
Page 14: ...12 RFS 60 Hz Components Location 4 2011 RFS Training Manual indd 12 10 3 2011 8 36 40 AM ...
Page 19: ...17 Performance Testing Procedures 6 2011 RFS Training Manual indd 17 10 3 2011 8 36 43 AM ...
Page 21: ...19 Component Testing Procedures 7 2011 RFS Training Manual indd 19 10 3 2011 8 36 44 AM ...
Page 26: ...24 Troubleshooting 8 2011 RFS Training Manual indd 24 10 3 2011 8 36 47 AM ...
Page 32: ...30 Schematic Wiring Diagrams 9 2011 RFS Training Manual indd 30 10 3 2011 8 36 49 AM ...
Page 38: ... U 4 2 H www acpsolutions com 2011 RFS Training Manual indd 36 10 3 2011 8 36 51 AM ...