Amana REMOTE CONDENSING UNIT User'S Information Manual Download Page 6

Electrical Power Supply

Many outdoor units include a crankcase heater. This
small heater warms the oil in the compressor for im-
proved lubrication. Once the needed temperature has
been reached, most of these heaters will shut off
automatically.
These heaters work effectively, but not rapidly. If your
outdoor unit has a crankcase heater and the power has
been disconnected from your outdoor unit for more than
two hours, you must connect electrical power to the
outdoor unit for at least four hours before setting the
thermostat so as to cause the unit to come on.
Not all outdoor units have crankcase heaters. If you are
not certain whether yours does or not, contact your
dealer.
If your outdoor air conditioning (not heat pump) unit
does have a crankcase heater, you may wish to shut it
off in the fall after cooling season is completely over. To
do this, simply open the disconnect switch which is near
the outdoor unit, or turn the proper circuit breaker at the
electrical panel to the OFF position. This could save you
a small amount of your winter electrical bills. If you
choose to do this, remember - a four hour warm-up
period with the electrical power connected is necessary
before running the air conditioner again in the spring. If
you forget this warm-up period, you run the risk of
severe equipment damage.

Refrigerant

Your comfort system uses R-22 as a refrigerant. R-22
has been used as a refrigerant for many years. It is
classified as an HCFC (

H

ydro

c

hloro

f

luoro

c

arbons).

Recent evidence suggests that HCFCs, when released
into the atmosphere, play a role in the thinning of the
earth’s ozone layer. Therefore, the EPA (Environmental
Protection Agency, a branch of the U.S. Federal Gov-
ernment) is beginning to implement new regulations
regarding the purchase, handling, and use of HCFCs
including R-22. Some of these regulations may increase
the cost of installation and service work on air condition-
ing and refrigeration equipment.
When your comfort system is operating properly, the
refrigerant is contained within airtight passages. No
refrigerant escapes into the atmosphere during normal
operation.
When repair or replacement of your comfort system
becomes necessary, it is essential that you hire a
qualified servicer to perform the work. A qualified
servicer will have the tools and training necessary to
ensure that EPA regulations are followed. U.S. residents
who ignore or intentionally violate the EPA regulations
are in violation of the law, and may be subject to fines or
other penalties.

General

Most of your questions can be answered by your local dealer. Check with your dealer first if you need further informa-
tion regarding the operation, maintenance, or service of your unit. If you have other matters that cannot be resolved
locally, or you need additional information regarding other heating and cooling products offered by us - please call:

CONSUMER INFORMATION LINE

AMANA TOLL FREE

1-877-254-4729 (U.S. only)

email us at: [email protected]

fax us at: (731) 856-1821

(Not a technical assistance line for dealers.)

Outside the U.S., call 1-713-861-2500.

(Not a technical assistance line for dealers.)

Your telephone company will bill you for the call.

Ask your participating dealer about our extended service plan. It adds to the strong
warranty with additional parts and labor coverage.

Asure

SM

 is a service mark of Maytag Corporation and is used under

license to Goodman Company, L.P.  All rights reserved.

Summary of Contents for REMOTE CONDENSING UNIT

Page 1: ...e serial plate for model identification Record this information on the last page of this booklet Please read this User s Manual carefully and follow the instructions given Keep it in a safe place for future reference Your warranty certificate is supplied with this unit Read it carefully and note what is covered Keep it and a copy of the bill received from your dealer in a safe place for future ref...

Page 2: ...of the items commonly found obstructing registers ATTENTION INSTALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer This includes all safety precautions and related items Prior to actual installation thoroughly familiarize yourself with this Instruction Manual Pay special attention to all safety warnings Often during installation or repa...

Page 3: ...______________ SERIAL ____________________________________ Important System Information AVERTISSEMENT WARNING HAZARDOUS MOVING PARTS Fan blades may start rotating automatically Do not apply power to this appliance or compressor if the compressor terminal cover has been removed or is not firmly in place PIÈCES MOBILES DANGEREUSES Les ailes du ventilateur peuvent commencer à tourner automatiquement ...

Page 4: ...s the indoor fan may continue to run for a short time after the compressor shuts off With most gas fur naces the indoor fan will start a short time after the burners are lit and will keep run ning for a short time after the burners shut off When your comfort system is not heat ing or cooling the fan will not run ON The indoor fan runs continuously WARNING To avoid possible equipment damage persona...

Page 5: ...y from the thermostat Heat from these items may cause the thermostat to falsely register the temperature of the room as warm when in actuality it may be quite cold Residential room thermostats must be exposed to the air in the room in order to accurately control room temperature It must not be covered Thermostats used in commercial buildings however can be covered if approved thermostat guards are...

Page 6: ...efore the EPA Environmental Protection Agency a branch of the U S Federal Gov ernment is beginning to implement new regulations regarding the purchase handling and use of HCFCs including R 22 Some of these regulations may increase the cost of installation and service work on air condition ing and refrigeration equipment When your comfort system is operating properly the refrigerant is contained wi...

Page 7: ...ticles CLEAN OUTSIDE COIL QUALIFIED SERVICER ONLY WARNING To avoid personal injury or death due to electrical shock disconnect the electrical power before cleaning the coil s Air must be able to flow through the outdoor unit of your comfort system Do not construct a fence near the unit or build a deck or patio over the unit without first dis cussing your plans with your dealer or other qualified s...

Page 8: ...atures that may automatically shut off the unit under abnormal operating conditions If your system does not operate normally take time to perform the following checks before requesting service A couple of simple checks may allow you to avoid a service call If the following steps do not resolve the problem contact a qualified servicer for further troubleshooting and or repairs Do not attempt troubl...

Reviews: