20 (Default Cool Mode Set Temp):
Determines the default
set temperature that is used when first selecting cool
mode.
98 (Delay Bypass):
Contractor/Installer mode, turns
off the compressor delays for testing the system;
returns automatically to normal operation after 10
minutes.
99 (RESET):
Returns all settings back to factory defaults.
TO ENTER SETTINGS MENU:
With thermostat powered,
move System Mode switch to
the OFF position. Press and
hold BOTH Up and Down
buttons for at least 5 seconds,
until the screen changes.
TO CHANGE AN ENTRY:
Use the Up or Down buttons
to change the setting option.
TO ADVANCE TO THE NEXT MENU ITEM:
Press BOTH the Up and Down
buttons together.
TO RETURN TO THE MAIN THERMOSTAT SCREEN:
Press BOTH the Up and Down
buttons together after last
menu item exits the settings
menu.
Waiting 1-Minute with no button presses will exit the
settings menu with all items saved as they were last
shown on the display screen.
8) INSTALLER SETTINGS
MENU# SETTING
OPTIONS
01
Scale
F
, C
02
Temp. Calibration
Zero
, -5F to +5F
(-3C to +3C)
--
04
Max. Heat
60F to 90F
(80F)
(16C to 32C)
05
Min. Cool
60F to 80F
(65F)
(7C to 24C)
--
09
Swing /
Temp. Differential
±0.25F (±0.14C)
±0.50F (±0.28C)
±1.00F (±0.56C)
±2.25F (±1.25C)
--
17
Backlight Always On
Off=Turn off 10 sec
On=Always On
18
Use default set temp.
after mode change
ON: Uses default
temps
OFF: Use last temp per
mode
19
Default heat mode set
temp.
70F (21C)
60F to max heat set temp
20
Default cool mode set
temp
74F (23C)
60F to max set temp
--
98
Compressor
Protection Bypass
No=Delays Remain
Yes=Suspend Delay
99
RESET
No=Save and Exit
Yes=Full Reset
SETTING DESCRIPTIONS:
01 (Scale):
Displayed temperatures shown in F/C
degrees.
02 (Temp. Calibration):
Gives user flexibility to adjust
the perceived measured temperature that is used for
thermal control.
04 (Max. Heat):
Sets the maximum temperature that
a user can adjust the target temperature to for
heating.
05 (Min. Cool):
Sets the minimum temperature that
a user can adjust the target temperature to for
cooling.
09 (Swing / Temp. Differential):
Determines how
wide or narrow the temperature control band is
between cut-in and cut-out.
17 (Backlight Always On):
Allows the display
backlight to remain on constantly, or turn off
automatically after 10 seconds.
18 (Set Temp After Mode Change):
Determines if the
thermostat recalls the last used set temperature per
mode, or uses a default set temperature when the
mode is changed manually.
19 (Default Heat Mode Set Temp):
Determines the default
set temperature that is used when first selecting heat
mode.
53608