Amana PBE093B35MB Installation Instructions And Owner'S Manual Download Page 3

3

WARNING

To prevent electrical shock, property
damage, personal injury, or death, do not
remove grounding prong from plug.  Follow
all operating instructions.

Installation Instructions

To ensure that the unit operates safely and efficiently, it must
be installed, operated, and maintained according to these
installation and operating instructions and all local codes
and ordinances, or, in their absence, with the latest edition
of the National Electrical Code.  The proper installation of this
unit is described in the following sections.  Following the
steps in the order presented should ensure proper installa-
tion.

SLEEVE INSTALLATION

In order for condensate water to drain properly inside the unit,
the sleeve must be installed properly:

Level from right to left.

A slight downward pitch from the indoor side to the
outdoor side as shown in Figure 3.

Refer to the Installation Instructions supplied with the wall
sleeve for a complete description of the installation proce-
dure.

NOTE: Wall sleeve (PBWS01A ) is not shipped with chassis
and must be purchased separately.

Wall

Sleeve

Outside

Wall

Outside

Inside

Level

1/4 Bubble

Tilt To

Outside

Figure 2

REAR LOUVER PANEL

A TWKGSLV rear louver panel kit is required for unit
installation into an existing Amana

®

 brand 26” wall sleeve.  A

TWEAK2 or TWFAK2 adapter kit is required for unit instal-
lation into an existing 27” wall sleeve.  The rear louver panel
directs air flow for proper unit operation and protects the
outdoor coil.  The panel must be installed before installing the
chassis.  These kits are not supplied with the unit.  Refer to
the Installation Instructions supplied with the rear louver
panel kit for a complete description of the installation
procedure.

CHASSIS INSTALLATION

1. Remove front grille. See Figure A.

Lift up on
Filter Handle

Figure A

The front grille can be removed for more thorough cleaning
or to make the model and serial numbers accessible. To
remove, pull the filter out and remove the two grille screws.

Grille

Tab

Pull the grille out from the bottom and lift up from the tabs
on the top of the case.

2. Remove the grounding screw and wire next to the

grounding symbol on right side of chassis control panel
(Figure 3). Attach other end of ground wire to the hole
in the bottom right side of the sleeve with #8 x 3/8” blunt
point sheet metal screw. The hole on the sleeve is
indicated by grounding symbol on the sleeve.  Slide
chassis part of the way into the sleeve and reattach the
ground wire back to the hole on the right side on the
control panel area next to the grounding symbol.

Summary of Contents for PBE093B35MB

Page 1: ...its safe use Safety is a matter of common sense a matter of thinking before acting Most dealers have a list of specific good safety practices follow them The precautions listed in this Installation M...

Page 2: ...k upperstyrofoam shipping blocks and styrofoam corner posts 3 Remove the front assembly 4 Lift the unit from the remaining carton 5 Disposeofthecardboardandstyrofoamatanapproved Recycle Center Check a...

Page 3: ...GSLV rear louver panel kit is required for unit installationintoanexistingAmana brand26 wallsleeve A TWEAK2 or TWFAK2 adapter kit is required for unit instal lation into an existing 27 wall sleeve The...

Page 4: ...hassis into the sleeve Ensure thatthegroundwireisnotpinchedorinthepathofthe condenserfan 5 Loosen locking plate screw and rotate tab with tab behind wall case flange See Figure C then tighten locking...

Page 5: ...becirculatedandconditioned When set at OPEN some inside air is exhausted outside Locating Hole Locating Hole Screw Hole Screw Hole OPEN position Mesh end toward back CLOSE position Mesh end toward fro...

Page 6: ...rnings and cautions WARNING To avoid the risk of electrical shock personal injury or death do not service this unit without first opening all disconnects and or removing the unit cord set plug from th...

Page 7: ...ovide a warmer one NOTE Ifthefancycleswitch seeAdditionalControlInputs is in the CYCLE mode both the compressor and fan will cycle on and off during the cooling modes Wait3minutestorestart WARMER COOL...

Page 8: ...ssembly underneath the control knob Figure 9 The fan cycle switch sets the operational mode of the fan In the NORMAL position the fan will run continuously whenever the unit is in the heat or cool mod...

Page 9: ...tions theunit should be removed from the sleeve and completely cleaned once a year At that time any scratches or blisters on the painted surfaces should be sanded and repainted OUTDOORCOILCLEANING The...

Page 10: ...RRGPDQ RQVXPHU IIDLUV DW WKH QXPEHU RU DGGUHVV ORFDWHG DW WKH ERWWRP RI WKLV FHUWLILFDWH RU ZDUUDQW FUHGLW WKH GHIHFWLYH SDUW PXVW EH UHWXUQHG WR DQ PDQD KHDWLQJ DQG DLU FRQGLWLRQLQJ SURGXFWV GLVWULE...

Reviews: