28
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Illustration Component
Test
Results
208
COM
230
120
Auto Transformer
230
208
120
0
Discharge Capacitors
Remove all wires from terminals.
Measure resistance from:
230 to 0 ...........................................................
208 to 0 ...........................................................
120 to 0 ...........................................................
42.4 .
38.6 .
21.5 .
1
2
3
4
7
6
5
8
Terminal 1
230 V
Terminal 2
Common
Terminal 3
208 V
Transformer
# 4
# 1
# 3
# 2
# 5
# 6
# 7
# 8
1.0 F
-300 MA
-300 MA
1.0 F
Discharge Capacitors
Remove all wires from terminals.
Measure resistance from:
Terminal 1 to 2................................................
Terminal 1 to 3................................................
Terminal 5 to 6................................................
Terminal 7 to 8................................................
Terminal 4 to Ground screw on transformer...
Terminal 4 to any other terminal.....................
Gray
Violet
Red
1
2
3
1.0 .
Less than 1 .
Less than 1 .
Less than 1 .
30 .
Infinite resistance. If not, replace
transformer.
Primary /
Logic
Secondary
Mo nitor
Interlock switch
assembly
Disconnect wires to switch.
With door open measure resistance from:
Terminal C to NC Monitor..........................
Terminal C to NO Primary / Logic..............
Terminal C to NO Secondary ....................
With door closed measure resistance from:
Terminal C to NC Monitor..........................
Terminal C to NO Primary / Logic..............
Terminal C to NO Secondary ....................
Door Closed
Primary / Logic C
NC
NO
C
C
NO
Secondary
Monitor
Continuity.
Infinite.
Infinite.
Infinite.
Continuity.
Continuity.
Touch Panel
Assembly
Continuity is indicated as 100 and below.
Pin 1:
Ground.
Pad
1
2
3
4
5
6
7
8
9
0
Start
Stop/Reset
Power Level
X 2
Time Entry
Pins
8 & 10
7 & 10
6 & 10
5 & 10
4 & 10
3 & 10
8 & 9
7 & 9
6 & 9
5 & 9
4 & 9
4 & 8
5 & 8
6 & 8
7 & 8
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Wire Harness
Test continuity of wires ................................... Continuity.
Some models
Sample - Refer to Product
Tech Sheet for proper Ohm
resistance value.
Summary of Contents for HDC-60
Page 3: ...1 Important Safety Information 1 ...
Page 13: ...11 HDC 60 Hz Components 4 ...
Page 18: ...16 Components Sample Door Assembly Door comes in two styles see through door and solid door ...
Page 19: ...17 Disassembly Inner door window removal Switch replacement door adjustment 5 ...
Page 26: ...24 Airflow 7 ...
Page 27: ...25 Air filter must be in place and cleaned regularly Some Models ...
Page 28: ...26 Component Testing Procedures 8 ...
Page 34: ...32 Troubleshooting Intial Power Up Standby Condition Cook Condition 9 ...
Page 38: ...36 Wiring Diagrams Schematics 10 ...
Page 42: ...40 Schematic Diagram Sample w Invensy Control ending at S N 0911102347 ...
Page 43: ...41 Notes ...