background image

4

To prevent death, personal injury or property damage due to electrical shock, disconnect electrical power to this furnace
before servicing or performing maintenance.

WARNING

     COOLING

YL YELLOW
OR ORANGE
VT VIOLET
GN GREEN
BK BLACK
BR BROWN
WH WHITE

BU BLUE
GY GRAY
RD RED

COLOR CODE

LOW VOLTAGE

LOW VOLTAGE FIELD

HI VOLTAGE

HI VOLTAGE FIELD

  HEATING BLOWER SPEED

FURNACE MODEL

MOTOR TO "HEAT"

FACTORY WIRED BLOWER MOTOR TO CONTROL CONNECTIONS

BLOWER SPEED

SEE 
INSTALLATION 
INSTRUCTIONS 
TO DETERMINE 
PROPER 
COOLING 
BLOWER SPEED.

3

MOTOR

SPEEDS

LOW

SPEED

GUX: 070X30*,090X50*
GUD: 090X35*,090X50*

BU-23

MED

4

  IMPORTANT:

4. UNUSED BLOWER MOTOR LEADS MUST BE PLACED ON "PARK" TERMINALS OF CONTROL OR TAPED.

READ BEFORE OPERATING OR SERVICING THIS UNIT.

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. AMANA SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE 
   REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING
   OF AT LEAST 105C. USE COPPER CONDUCTORS ONLY.

5  IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME DISCARD JUMPER BEFORE
   CONNECTING BLOWER LEADS.

RD-24

GUX: 090X35*,115X50*
GUC: 070X30*,115X50*
     090X35*
GUD: 070X30*,115X50*

HI

BK-26

4

*

**

6  DIAGNOSTIC LIGHT:STEADY=REPLACE CONTROL;1 FLASH=LOCKOUT;2 FLASHES=PS STUCK CLOSED;
   3 FLASHES=PS STUCK OPEN;4 FLASHES=OPEN HIGH LIMIT SWITCH;
   5 FLASHES=OPEN ROLLOUT CONTROL;
   CONTINUOUS FLASHING=FLAME-NO CALL FOR HEAT

11165501  REV. 0

BR-21

PRIMARY

ROLLOUT
LIMIT (RL)

FLAME SENSOR

COMBUSTION

BLOWER

(CB)

DOOR SWITCH (CLOSED
WHEN DOOR IN PLACE)

115V

FIELD

CONNECT

AIR

CIRCULATION

BLOWER

(ACB)

CAPACITOR
  (CAP)

BR

BR

X

F

M

R

I

G

N

I

N

D

C

O

O

L

H

E

A

T

P

A

R

K

P

A

R

K

L

I

N

E

X

F

M

R

L

I

N

E

C

I

R

W

Y

LO AD

LINE

TRANSFORMER

#29 OR (MED LOW)

#26 BK (HI)
#23 BU (MED)

#24 RD (LOW)

PRESSURE SWITCH (PS)

NC

NO

COM

**

*

CONTROL

RD-22

BK-6

BK-3

WH

BK

GY-47

VT-14

OR
-16

YL

-11

OR-16

BU-25

BK-1

WH-2

12

1

4

7

10

11

8

5

2

3

6

9

BR-21

BU
-36

VT

-14

GY
-25

BK-6
BK-1

VT

-55

RD
-22

OR-3

BU-15

BU-36

VT

-55

5

6

GAS

VALVE

(GV)

THERMOSTAT

CONNECTIONS

WARNING:DISCONNECT POWER BEFORE 
SERVICING.WIRING TO UNIT MUST BE 
PROPERLY POLARIZED AND GROUNDED.

WARNING:DISCONNECT POWER 
BEFORE SERVICING.WIRING TO 
UNIT MUST BE PROPERLY 
POLARIZED AND GROUNDED.

IGNITOR

WH-

23

WH-33

WH

GND

N

L1

LIMIT

R

G

C

ELECTRICAL BOX

3

2

1

H

U

M

E

A

C

H

U

M

E

A

C

115V FIELD

CONNECT

HUMIDIFIER

115V FIELD

CONNECT

ELECTRONIC

AIR CLEANER

H

O

T

 120

V

A

C

NE

UT
RA

L

 1

2

0

V

A

C

CI
RC

U

L

A

T

O

R

 B

L

O

W

E

R

TH

FP

HL
O

RO

1

TR

MV

GN

D

HL
I

PS

RO

2

MV

GUC: 045X30*
GUD: 045X30*

MED

3

BU-23

P

C

M

WH

GY-47

YL-11

BU-25

GY-25

OR-3

RD-44

RD-44

GN

GN

PRIMARY

RL

N

L1

DOOR

SWITCH

GND

IGNITOR

GV

CB

PS

NO

C

I
N
D

L
I
N
E

N
E
U

120 V

TRANS-

FORMER

 24 V

S
E
N
S
O
R

CAP

ACB

Y

W

THERMOSTAT
CONNECTIONS

CONTROL

6

5

TERMINAL ORDER REARRANGED FOR CLARITY

L

I

M

I

T

**

*

F
L
A
M
E

R

G

C

C

NC

NO

E
A
C
 

H
O
T

E
A
C
 

N
E
U

H
U
M
 

H
O
T

H
U
M
 

N
E
U

L
I
N
E

H
O
T

X
F
M
R

H
O
T

X
F
M
R

N
E
U

 
 
 
 

 
T
H

 
 
 
 

 
P
S

 
 
 
 

H
L
I

 
 
 
 

H
L
O

 
 
 
 

 
M
V

 

 
M
V

 

C
O
O
L

H
E
A
T

 
 

P
A
R
K

 
 
 

P
A
R
K

C
I
R
 

N
E
U

 
 
 
 

I
G
N

 
 
 
 

 
F
P

 
 
 
 

G
N
D

 
 
 
 

 
T
R

 
 
 
 

R
0
2

 
 
 
 

R
0
1

RD-44

RD-44

* MANUFACTURER'S VARIABLE LETTER

GUX: 070X40*   
GUC: 090X50*
GUD: 070X40*

MED LOW

4

OR-29

GUX: 045X30*
GUC: 070X40*

4

LOW

RD-24

Reviews: