Amana CT-DPTAC Catalog Download Page 10

10

www.amana-ptac.com

CT-DPTAC

P

ower

 c

ord

 c

onFiguraTion

i

nTake

 a

ir

 F

ilTers

It is extremely important to clean the inlet air filters once a month (or more often if operated in dusty or dirty locations or 
conditions)  to properly maintain  the operational  performance of the PTAC unit.  The two intake air filters (constructed of 
durable polypropylene) can be easily inserted into the cabinet front using the cabinet filter guides. Before cleaning the intake 
filters, turn the unit off by setting the mode switch to the OFF position. Filters should be cleaned as required.The following 
procedure is used to remove the intake filters:
1. Facing the unit, pull up on the filter handles located at the front top of the unit.
2. Pull each filter upward and remove.
3. Clean filters with vacuum or with running water. Reverse this procedure to reinstall the filters.

Note:  Accessory filter kits are available from your sales person. All filters are permanent and cleanable. Consult your  

       I&O Manual for other monthly cleaning instructions.

m

onTHly

 m

ainTenance

s

Pare

 F

ilTers

 

Helps keep dirt and lint out of the air and off the coil, 
thus  increasing  the  unit's  efficiency.  Amana®  brand 
filters are easy to remove, wash and replace.

FK10A

10-pack - A Series

FK10B

10-pack - B, C & D Series

FK10E

10-pack - E Series (This 
model requires 2 filters 
per change.)

r

ePlacemenT

 c

Harcoal

 F

ilTer

 k

iT

Absorbs  airborne  odors  caused  by  cigarette,  pipe 
or  cigar  smoke  and  odors  caused  by  mold,  mildew, 
etc.  Filters  are  made  of  polyester  fibers  coated  with 
activated  charcoal  and  are  individually  wrapped. 
These  filters  are  permanent  and  can  be  washed  or 
cleaned.  Call  your  Amana®  brand  PTAC  sales  person 
for details. 10 filters per pack.

CFK10A

10-pack - A Series (R-22)

CFK10B

10-pack - B, C & D Series 
(R-22)

277V Rating Power Cord Plugs

NEMA 7 Configuration

G

W

20 amp

G

W

30 amp

250V Rating Power Cord Plugs with LCDI Device

NEMA 6 Configuration

Power Cord Plugs

15 amp

20 amp

30 amp

Power Receptacle Configuration

NEMA6-15R; 250V 
receptacle used on 
230/208V units

NEMA6-20R; 250V 
receptacle used on 
230/208V units

NEMA6-30R; 250V 
receptacle used on 
230/208V units

NEMA7-20R; 277V receptacle  
used on 265V units

NEMA7-30R; 277V receptacle  
used on 265V units

All units come with factory-installed power cords.

All units less than 250 volts come with LCDI device.

Summary of Contents for CT-DPTAC

Page 1: ...Supersedes 6 12 Packaged Terminal Air Conditioners and Heat Pumps with our DigiSmart Control Board EMS PTAC Catalog First Year Warranty Parts Labor Second through Fifth Year Parts Labor on certain se...

Page 2: ...one of the most comprehensive warranties in the industry First Year parts labor second through fifth years parts labor on certain sealed system components second through fifth years on certain functi...

Page 3: ...ostat and unit control panel continue to control the unit providing flexibility and home like system control Installation requires no more than pressing two buttons No need to run wires or make electr...

Page 4: ...room temperature Best of all no wires to run The PTAC and Thermostat connect at the press of a button and are permanently linked The thermostat and PTAC work in sync to display accurate temperature Th...

Page 5: ...he network for additional rooms properties System Verification Global Setbacks EMS Configuration Site Statistics Battery Notices Email Reporting Unit Health Unit Code Alerts Temp Limiting Each PTAC ca...

Page 6: ...tandard Outdoor Grille SGK01B Single Pack SGK01TB Stonewood Beige Architectural Outdoor Grille AGK01CB Anodized Aluminum Silver AGK01DB Dark Bronze Brown AGK01TB Stonewood Beige AGK01WB Amana White AG...

Page 7: ...in 15 20 or 30 amp can be used with Amana brand sub bases It gives overcurrent protection and its location allows you to turn the unit on or off without tools CBK3 C Circuit Breaker Kit Duct Extension...

Page 8: ...ny thermostat other than those listed must be submitted to Goodman Company L P for approval prior to use Model Heat Stages Cool Stages Fan Speed of Wires Required Temp Limiting Backlit Display Type Sh...

Page 9: ...1E Web enabled Platform Server DL01E Web enabled Platform Server Link Remote Temperature Sensor Unit can be wired to sense room temperature away from the PTAC to have accurate readings RTS03 Remote wa...

Page 10: ...ilters Helps keep dirt and lint out of the air and off the coil thus increasing the unit s efficiency Amana brand filters are easy to remove wash and replace FK10A 10 pack A Series FK10B 10 pack B C D...

Page 11: ...CT DPTAC www amana ptac com 11 Notes...

Page 12: ...without notice 2013 Goodman Company L P Houston Texas Printed in the USA Packaged Terminal Air Conditioners and Heat Pumps with Control Board 7 Button Control Pad One Touch Activation Total Fan Contr...

Reviews: