10
www.amana-ptac.com
CT-DPTAC
P
ower
c
ord
c
onFiguraTion
i
nTake
a
ir
F
ilTers
It is extremely important to clean the inlet air filters once a month (or more often if operated in dusty or dirty locations or
conditions) to properly maintain the operational performance of the PTAC unit. The two intake air filters (constructed of
durable polypropylene) can be easily inserted into the cabinet front using the cabinet filter guides. Before cleaning the intake
filters, turn the unit off by setting the mode switch to the OFF position. Filters should be cleaned as required.The following
procedure is used to remove the intake filters:
1. Facing the unit, pull up on the filter handles located at the front top of the unit.
2. Pull each filter upward and remove.
3. Clean filters with vacuum or with running water. Reverse this procedure to reinstall the filters.
Note: Accessory filter kits are available from your sales person. All filters are permanent and cleanable. Consult your
I&O Manual for other monthly cleaning instructions.
m
onTHly
m
ainTenance
s
Pare
F
ilTers
Helps keep dirt and lint out of the air and off the coil,
thus increasing the unit's efficiency. Amana® brand
filters are easy to remove, wash and replace.
FK10A
10-pack - A Series
FK10B
10-pack - B, C & D Series
FK10E
10-pack - E Series (This
model requires 2 filters
per change.)
r
ePlacemenT
c
Harcoal
F
ilTer
k
iT
Absorbs airborne odors caused by cigarette, pipe
or cigar smoke and odors caused by mold, mildew,
etc. Filters are made of polyester fibers coated with
activated charcoal and are individually wrapped.
These filters are permanent and can be washed or
cleaned. Call your Amana® brand PTAC sales person
for details. 10 filters per pack.
CFK10A
10-pack - A Series (R-22)
CFK10B
10-pack - B, C & D Series
(R-22)
277V Rating Power Cord Plugs
NEMA 7 Configuration
G
W
20 amp
G
W
30 amp
250V Rating Power Cord Plugs with LCDI Device
NEMA 6 Configuration
Power Cord Plugs
15 amp
20 amp
30 amp
Power Receptacle Configuration
NEMA6-15R; 250V
receptacle used on
230/208V units
NEMA6-20R; 250V
receptacle used on
230/208V units
NEMA6-30R; 250V
receptacle used on
230/208V units
NEMA7-20R; 277V receptacle
used on 265V units
NEMA7-30R; 277V receptacle
used on 265V units
All units come with factory-installed power cords.
All units less than 250 volts come with LCDI device.