6
AVPVC**14
*Revision level that may or may not be designated.
NOTE: Airflow selection should meet the minimum requirements as mentioned in the air handler installation instructions.
NOTE:
Airflow data shown applies to the electric heat only in either legacy mode or communicating mode operation.
* Within thermostat user menu, CTK04 communicating thermostat will display 20 kW for OFF-OFF-ON dip switch selection and
21 kW for OFF- OFF-OFF dip switch selection.
NR- Not rated
+
For match up with a 2 ton outdoor unit: Heater kit application shall not exceed 10 kW.
Airflow for 5 kW up to 10 kW heater kits shall be set to 850 cfm speed tap of ON-ON-ON.
++
For match up with a 3 ton outdoor unit: Heater kit application shall not exceed 15 kW.
Airflow for 5 kW up to 15 kW heater kits shall be set to 1300 cfm speed tap of ON-OFF-ON.
Airflow for 5 kW up to 20 kW heater kits shall be set to 1500 cfm speed tap of ON-OFF-OFF
** 3 kW heater kit is not applicable for this indoor application.
AVZC20***1**
Model Name
TXV-Kit
AVZC200241**
TXV-V24
AVZC200361**
TXV-V36
AVZC200481**
TXV-V48
AVZC200601**
TXV-V60
Htr kW
9
10
11
AVPVC24C14**
AVP
AVPV+
AVP+
3
ON
ON
ON
730
850**
NR
NR
5
ON
ON
OFF
780
1250
1250
1250
6
ON
OFF
ON
850
1300
1300
1300
8
ON
OFF OFF
950
1500
1500
1500
10
OFF
ON
ON
1025
1550
1550
1550
15
OFF
ON
OFF
NR
1720
1720
1780
19*
NR
NR
NR
NR
20
NR
1800
1815
1850
21 or 25*
OFF OFF OFF
NR
NR
1850
1850
ELECTRIC HEAT AIRFLOW TABLE
OFF OFF
ON
Models
HK
SX
0
3
X
C
HK
SX
0
5
X
C
HK
SX
0
6
X
C
HK
SX
0
8
X
C
HK
SX
1
0
X
C
HK
SC
0
5
X
C
HK
SC
0
8
X
C
HK
SC
1
0
X
C
HK
SC
1
5
X
A
HK
SC
1
5
X
B
HK
SC
1
5
X
F
HK
SC
1
9
CA
HK
SC
1
9
CB
HK
SC
2
0
D
A
HK
SC
2
0
D
B
HK
SC
2
0
X
F
HK
SC
2
5
D
C
AVPVC24C14A*
X
X
X
X
X
X
X
X
AVPVC36D14A*
X
X
X
X
X
X
X
X
X
X
X
X
X
AVPVC48D14A*
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AVPVC60D14A*
X
X
X
X
X
X
X
X
X
X
X
X
X
X