Amana AMVS96-U Quick Start Manual Download Page 4

4

www.amana-hac.com

SS-

AMVS96-U

SS-

AMVS96-U

www.amana-hac.com

5

AMVS96-U Dimensions

5

19⅝

34½

¾

19½

¾

 B
 C

23

2⅜

1⅞

2

5

19⅝

23

24⅞

31⅞

A

21⅛

 2⅝

14

23

1⅜

¾

28¾

2⅜

1⅞

2

1⅞

26½

23½

Folded Flanges

22

Unfolded Flanges

D

Unfolded Flanges

E

Folded Flanges

Air

Discharge

Air

Discharge

LEFT SIDE VIEW

FRONT VIEW

RIGHT SIDE VIEW

Condensate Drain

Trap Exterior

Connection

(Right or Left Side)

¾

 PVC 

Vent/ Flue Pipe

2" PVC

Alternate 

Vent/ Flue

Location

Right-Side

Drain Trap

Exterior Holes

High-Voltage

Electrical Outlet

Alternate

Gas Supply

Low-Voltage

Electrical Outlet

Standard 

Gas Supply

Location

Center Dimple

For Alternate

Air Intake Pipe

3"

 OD Hole

Air Intake

2" Pipe

Left-Side

Drain Trap

Exterior Holes

High-Voltage

Electrical Outlet

Low-voltage

Electrical Outlet

Minimum Clearances to Combustible Materials

Position

Sides

Rear

Front

Bottom

Flue

Top

Upflow

0"

0"

3"

C

0"

1"

Horizontal

6"

0"

3”

C

0"

6"

C = If placed on combustible floor, the floor MUST be wood ONLY.

Air 

Discharge

Air  

 

Return

Model

W

D

H

A

B

C

D

E

AMVS960603BU

17½"

28⅞"

34½"

17½"

16"

13⅞"

12⅛"

13⅝"

AMVS960805CU

 21" 

28⅞"

34½"

 21" 

19½"

17⅞"

16"

17½"

Summary of Contents for AMVS96-U

Page 1: ...ed draft blower Self diagnostic control board with constant memory fault code history output to 3 x 7 segment display Eligible for installation in California s South Coast Air Quality Management Distr...

Page 2: ...Brand Major Minor Revisions Not used for inventory control Configuration NOx M Upflow Horizontal U Ultra Low NOx Cabinet Width Motor B 17 C 21 E Multi Speed ECM V Variable Speed ECM ComfortBridge Maxi...

Page 3: ...ional Combustion Air Pipe is dependent on installation code requirements and must be 2 or 3 diameter PVC Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire size should be deter...

Page 4: ...Trap Exterior Holes High Voltage Electrical Outlet Alternate Gas Supply Low Voltage Electrical Outlet Standard Gas Supply Location Center Dimple For Alternate Air Intake Pipe 3 OD Hole Air Intake 2 P...

Page 5: ...RANGE AMVS960603BUA 30 60 45 AMVS960805CUA 30 60 45 CFM RISE CFM RISE Recommended CFM for Heat Mode Expected Temperature Rise 1185 45 1580 45 Lowest Recommended CFM for Heat Mode Expected Temperature...

Page 6: ...OR SERVICING WIRING EQUIPMENT GND ON SOME MODELS INTERNAL TO PROT DEVICE INTEGRATED CONTROL PK C USE COPPER CONDUCTORS ONLY AT LEAST 105 IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE R...

Page 7: ...BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800...

Page 8: ...ademark of Maytag Corporation or its related companies and is used under license All rights reserved Our continuing commitment to quality products may mean a change in specifications without notice 20...

Reviews: