Amana AMA05KF Use And Care Manual Download Page 9

POWER

       Turn air conditioner on or off. 

LOW

     Low speed fan operate with optional cooling.

HIGH

 

   High speed fan operate with optional cooling.

This automatically controls the temperature of indoor air.Turn 
the knob so that the arrow points to the cooler marks for more 
moderate cooling.

1. Turn the SPEED mode switch to the “HI“ or the “LOW“ setting.

2.  Set the thermostat control to the “FAN ONLY” setting .

1. Turn the SPEED mode switch to the “HI“ or the  “LOW“ setting.

2.  Set the thermostat control to the desired temperature.(The 

mid-point is a good starting position .) 

If the room temperature is not satisfactory after a reasonable 

time,adjust the control to a cooler setting,as appropriate.

1. Turn the SPEED mode switch to the “HI“ setting.

2.  Set the thermostat control to the MAX COOL temperature 

mark.

1. Turn the SPEED mode switch to the “LOW“ setting.

2.  Set the thermostat control as needed.

Operating your air conditioner properly helps you to obtain the
best possible results.

This section explains proper air conditioner operation.

IMPORTANT:

   If you turn off the air conditioner, wait at least 3 minutes before 

turning it back on. This keeps the air conditioner from blowing a 
fuse or tripping a circuit breaker.

    Do not try to operate your air conditioner in the Cool mode when 

outside temperature is below 65°F (18°C). The inside evaporator 
coil will freeze up, and the air conditioner will not operate 
properly.

NOTE:

 In the event of a power failure, your air conditioner will 

operate at the previous settings when the power is restored.

AIR CONDITIONER USE

Starting Your Air Conditioner

SPEED

Normal Fan

Normal cooling

Maximum cooling

Quieter operation

9

A

When your air conditioner is operating normally, you may hear
sounds such as:

   Droplets of water hitting the condenser, causing a pinging or 

clicking sound. The water droplets help cool the condenser.

  Air movement from the fan.

  Clicks from the thermostat cycle.

  Vibrations or noise due to poor wall or window construction.

   A high-pitched hum or pulsating noise caused by the modern 

high-efficiency compressor cycling on and off.

Changing Air Direction

Use the tab to direct the airflow right or left.

Normal Sounds

A. Tab

Summary of Contents for AMA05KF

Page 1: ...TACI N ManualdeUsoyCuidado Si tiene preguntas respecto a las caracter sticas funcionamiento rendimiento partes accesorios o servicio t cnico llame al 1 888 842 2440 CLIMATISEUR DEPI CE Guided utilisat...

Page 2: ...raci n de la ventana para la instalaci n 17 Coloque el acondicionador de aire en su lugar 18 Complete la instalaci n 19 C MO USAR EL ACONDICIONADOR DE AIRE 20 C mo poner en marcha su acondicionador de...

Page 3: ...n follow instructions instructions DANGER WARNING IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow these basic precaut...

Page 4: ...of plug on the power supply cord This air conditioner must be grounded This air conditioner is equipped with a power supply cord having a 3 prong grounding plug The cord must be plugged into a mating...

Page 5: ...ee 3 13 32 screws attach the top channel to the air conditioner NOTES The Reset button must be pushed in for proper operation The power supply cord must be replaced if it fails to trip when the test b...

Page 6: ...the width of the window opening 2 Mark the center line on the inside windowsill 3 Install the Window lock bracket behind the inner windowsill with the short side of Window lock bracket as shown Use t...

Page 7: ...left hand curtain out until it ts into the window channel 2 Use a 1 8 drill bit to drill a starter hole through the top hole in the side curtain and into the window sash 3 Insert one 1 of the 31 32 s...

Page 8: ...2 Place the window lock bracket as shown Use a 1 8 drill bit to drill a starter hole through the hole in the window lock bracket and into the upper window 3 Attach the window lock bracket to the uppe...

Page 9: ...n explains proper air conditioner operation IMPORTANT If you turn off the air conditioner wait at least 3 minutes before turning it back on This keeps the air conditioner from blowing a fuse or trippi...

Page 10: ...rm water with a mild detergent Do not wash the air lter in the dishwasher or use any chemical cleaners Air dry the air lter completely before replacing to ensure maximum ef ciency 4 Replace the air lt...

Page 11: ...air conditioner in a location where the louvers are free from curtains blinds furniture etc The outside temperature is below 65 F 18 C Do not try to operate your air conditioner in the cooling mode w...

Page 12: ...ll Haier America toll free 1 888 842 2440 Our consultants provide assistance with Features and speci cations on our appliances Installation information Use and maintenance procedures Repair parts sale...

Page 13: ...ice by other than an authorized dealer or service center 7 Decorative trims or replaceable light bulbs 8 Labor service transportation and shipping charges for the removal of defective parts and instal...

Page 14: ...rir o sufrir una lesi n grave INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica o lesiones cuando utiliza su acondicionador de aire tenga en cuen...

Page 15: ...ci n se indican los requisitos el ctricos espec cos Respete los requisitos en cuanto al tipo de enchufe en el cable de suministro de energ a Este acondicionador de aire debe tener conexi n a tierra Es...

Page 16: ...limentaci n ADVERTENCIA Conecte a un contacto de pared de conexi n a tierra de 3 terminales No quite la terminal de conexi n a tierra No use un adaptador No use un cable el ctrico de extensi n No segu...

Page 17: ...sula de traba de la ventana como se muestra Use los dos 2 tornillos para madera de 31 32 provistos La m nsula de traba de la ventana ayuda a sostener el acondicionador de aire en su lugar Aseg rese de...

Page 18: ...superior de la cortina lateral y en la hoja de la ventana 3 Introduzca uno de los tornillos de 31 32 en el agujero superior de la cortina del lado izquierdo y en la hoja de la ventana 4 Repita los pa...

Page 19: ...oja inferior de la ventana y contra el vidrio de la ventana superior A Parte superior de la hoja inferior de la ventana B Junta de espuma 2 Ubique la m nsula de traba de la ventana como se muestra Use...

Page 20: ...ximo Funcionamiento m s silencioso A Cuando su acondicionador de aire funciona normalmente puede o r sonidos tales como Gotitas de agua que golpean el condensador que provocan un sonido met lico o un...

Page 21: ...de volver a ubicarlo para garantizar una e ciencia m xima 4 Vuelva a colocar el ltro de aire 5 Cierre el panel frontal 6 Encienda el acondicionador de aire Limpiezadelpanelfrontal ADVERTENCIA Conecte...

Page 22: ...ratura Con gure el control de velocidad del ventilador en la con guraci n m s elevada El acondicionador de aire actual reemplaz un modelo anterior El uso de componentes m s e cientes puede hacer que e...

Page 23: ...la tienda ______________________________________ Domicilio de la tienda _____________________________________ Tel fono de la tienda ______________________________________ Conserve este folleto y la f...

Page 24: ...ue no sea el uso hogare o 6 Da os causados por otra reparaci n que no sea la brindada por un vendedor autorizado o centro de reparaciones 7 Terminaciones decorativas o bombillas de luz 8 Los gastos de...

Page 25: ...us ne suivez pas imm diatement les instructions IMPORTANTES INSTRUCTIONS DE S CURIT AVERTISSEMENT Pour r duire les risques d incendie de choc lectrique ou des blessures lors de l utilisation du climat...

Page 26: ...respect de ces instructions peut causer un d c s un incendie ou un choc lectrique Risque de choc lectrique Les caract ristiques lectriques pour votre climatiseur sont inscrites sur l tiquette du num...

Page 27: ...on 1 Brancher le l dans une prise trois branches mise terre 2 Appuyer sur RESET sur certains mod les une lumi re verte s allume 3 Appuyer sur TEST vous devriez entendre un clique le bouton RESET se d...

Page 28: ...Marquer d une ligne le centre de la fen tre 3 l aide de deux vis bois 13 32po installer les querres pour barrer la fen tre derri re le rebord int rieur de la fen tre avec le c t court de l querre pla...

Page 29: ...ou initial au travers du trou du haut du rideau et dans le ch ssis guillotine 3 Ins rer une vis 31 32po dans le trou du haut du rideau et dans le ch ssis guillotine 4 R p ter les tapes pour le rideau...

Page 30: ...Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique Risque de choc lectrique 1 Ins rer le scellant en mousse l arri re du haut du ch ssis guillotine abaiss et con...

Page 31: ...tionne normalement vous pouvez entendre des sons tels que Des gouttelettes d eau heurtant le condensateur et causant un clique ou un ping Les gouttes d eau aident refroidir le condensateur Le d bit d...

Page 32: ...air libre avant de le replacer pour un maximum d ef cacit 4 Replacer le ltre air 5 Fermer le panneau avant 6 Mettre en marche le climatiseur Nettoyagedupanneauavant AVERTISSEMENT Brancher sur une pri...

Page 33: ...fentes de ventilations sont bloqu es Installez le climatiseur un endroit o les fentes sont libres de rideaux de stores de meubles etc La temp rature ext rieure est de moins de 65 F 18 C Ne tentez pas...

Page 34: ..._____________ Nom du magasin__________________________________________ Adresse du magasin_______________________________________ Num ro de t l phone du magasin_____________________________ Conserver c...

Page 35: ...r paration faite par autre qu un d taillant ou centre de service autoris 7 Les dommages dus aux accessoires d coratifs ou aux ampoules rempla ables 8 Les co ts de main d uvre de service et de transpo...