-8-
HOW TO REMOVE RANGE FOR
SERVICING
Follow these procedures to remove appliance for
servicing:
1. Slide range forward to disengage range from the
anti-tip bracket.
2. Shut off gas supply to appliance.
3. Disconnect electrical supply to appliance.
4. Disconnect gas supply tubing to appliance.
5. Reverse procedure to reinstall. If gas line has been
disconnected, check for gas leaks after reconnection.
NOTE:
A qualified servicer should disconnect and
reconnect the gas supply.
The servicer
MUST
follow installation instructions
provided with the gas appliance connector and the
warning label attached to the connector.
6. To prevent range from accidentally tipping, range must
be secured to the floor by sliding rear leveling leg into
the anti-tip bracket.
SERVICE-PARTS INFORMATION
When your range requires service or replacement parts,
contact your dealer or authorized service agency. Please
give the complete model and serial number of the range
which is located on range model number plate.
Appliance Pressure Regulator Conversion
The unit appliance pressure regulator must be set to
match the type gas supply used. If converting from natural
gas to LP gas, the appliance pressure regulator must be
converted to regulate LP gas. If converting from LP gas to
natural gas, the appliance pressure regulator must be
converted to regulate natural gas.
To convert the appliance pressure regulator from one gas
to another, follow the instructions below:
S
Remove plastic dust cover from cap nut on top of
appliance pressure regulator. Remove cap nut from
appliance pressure regulator (plastic dust cover
comes off with nut). “IMPORTANT” remove plastic
dust cover from cap nut and reinstall on opposite
side of cap nut.
S
Reinstall cap nut to appliance pressure regulator and
replace dust cover.
“CAUTION”
be sure marking for
the type of gas to which appliance pressure regulator
has just been converted is visible in top of cap nut
before replacing plastic dust cover. (See figure 6).
NOTE:
If oven burner does not ignite, check oven gas
shut-off position at the regulator.
FIGURE 6