Page 1: ...symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be k...

Page 2: ...ed on the left side frame behind the storage drawer panel The range should be located for convenient use in the kitchen To eliminate the risk of burns or fire by reaching over heated surface units cab...

Page 3: ...n required between cutout and cabinet door or hinge NOTE 24 61 0 cm minimum when bottom of wood or metal cabinet is covered by not less than 1 4 0 64 cm flame retardant millboard covered with not less...

Page 4: ...the back of the range or inside the storage drawer in a clear plastic bag If connecting to a 4 wire system This range is manufactured with the ground connected to the neutral by a link The ground mus...

Page 5: ...range and be killed Connect anti tip bracket to rear range foot Reconnect the anti tip bracket if the range is moved Failure to follow these instructions can result in death or serious burns to child...

Page 6: ...re to follow these instructions can result in death fire or electrical shock Direct Wire Electrical Shock Hazard Disconnect power before servicing Use 8 gauge copper or 6 gauge aluminum wire Electrica...

Page 7: ...m 40 amp range power supply cord 3 wire connection Power supply cord 3 wire direct A circuit breaker 3 8 box or fused 1 0crn _ disconnect 7 6 crn 3 wire connection Direct wire 5 t A Removable retainin...

Page 8: ...wire F Line 1 black Connect line 2 red and line 1 black wires to the outer terminal block posts with 10 32 hex nuts Securely tighten hex nuts NOTE For power supply cord replacement use only a power c...

Page 9: ...hillips screwdriver to remove the ground link screw from the back of the range Save the ground link screw and the end of the ground link under the screw Pull the wires through the conduit on cord cond...

Page 10: ...in 2 8 N m 6 gauge aluminum 35 Ibs in 4 0 N m 3 Use 3 8 nut driver to connect the bare green ground wire to the center terminal block post with one of the 10 32 hex nuts F A 10 32 hex nut B Line 2 re...

Page 11: ...not operate check the following Household fuse is intact and tight or circuit breaker has not tripped Range is plugged into an outlet Electrical supply is connected See Troubleshooting in the Use and...