background image

Present the card face-on to the reader until you hear a "bleep". Cards can be presented in rapid

succession; there is no need, for example, to wait for UNLOCKED" to

efore presenting

another.

"

disappear b

If the reader has been enabled for user-code mode at the controller, you can gain access by pressing

the # key, entering your card number, then pressing the * key.

Specifications

Input voltage: 9-14Vdc.

Input current (excl. heater): 150mA @ nom. 12Vdc.

Operating temperature: -4 to 158 F (-20 to 70 C)

without heater.

Operating humidity: 15 to 90%, non-condensing.

Maximum read range: 2.5" (65mm).

Approvals: EN50133, R&TTE, IP656.

°

°

6

Using the Reader

0V

Connect shield at controller

end only (attach to case).

RX+

RX-

TX+

TX-

12V

Reader

Twisted pairs (use

Belden 9503 cable)

Controller

connections

(20mA current

loop)

The I/O terminal is for

connection to a RIM (see

the RIM Instructions).
On completion, re-secure

the reader to the backplate.

0V

TX+
Do not use

TX-

I/0

RX+

RX-

+V

4

Reader Connections

A reader Setup menu can be displayed by pressing the * and # keys simultaneously while power is

applied. You can use the menu to change the contrast and language used for the LCD (default English).

At the prompts, press * for No and # for Yes.

5

Reader Configuration

9600-0343.

Installation and User Instructions for S842 Readers,

Issue 1.0x4 2nd December 2003. AMAG Technology Ltd, 2003.

HID is a registered trademark of HID

Corporation. i

is a trademark of HID Corporation. Philips and

MIFARE are registered trademarks of Philips Electronics N.V.

FCC Notice:

This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions: (1) This device

may not cause harmful interference, and (2) this device must accept

any interference received, including interference that may cause

undesired operation.
Any unauthorized modification to this device may void the authority of

the user to operate it.

CLASS

©

About the Reader Messages

}

READY
UNLOCKED
ACCESS DENIED & LOCKED

ENTER PIN

– The lock is released and you may open the door.

– You do not have access rights to gain entry, or the reader

did not read your card properly (in this case, present it again).

– Enter your PIN. If you make a mistake, the message INCORRECT PIN is

momentarily displayed, followed by ENTER PIN, to prompt you to try again.

The reader is waiting for a valid card to be presented.

(Flashing or steady)

– These auxiliary indicators can be configured to operate in

conjunction with conditional commands.

Reviews: