![AM Solar 99-CMPGLD Manual Download Page 9](http://html1.mh-extra.com/html/am-solar/99-cmpgld/99-cmpgld_manual_2915652009.webp)
Programming:
The MPPT Charge Controller for AGM Batteries
Programming / Commissioning Your System - The Charge Controller
Charge Control Settings for AGM Batteries:
1. Download the “VictronConnect” App to your phone.
2. Open the App.
3. You’ll see a selection for your SmartSolar MPPT Charger, select it.
4. Type
000000
to login for the first time.
NOTE: To change the PIN code, go back one step to the main screen. Click on the
3 buttons to the right of the controller image, and select “Reset PIN Code”.
5. Click on the
gear
in the top right corner.
6. Click on “Battery”.
7. Click on the settings and adjust them acccordingly to match below:
- Battery voltage: 12V
- Max charge current: 20A (In this example)
- Use default charge settings: OFF
- Charger: ON
- Absorption voltage: 14.40 V
- Absorption Time Limit: 02:00
- Float voltage: 13.30 V
- Equalization voltage: 15.20 V
- Auto Equalization: DISABLE (OFF)
- Temperature Compensation: ON
- Temperature Compensation: -20.00