The mixer must stop operating immediately. If not, do not use the machine; call supervisor
and advise W & P Reedy.
4.5 Test the slide safety guard by sliding the guard open and then closing and pushing the
green start button again. The mixer must stop operating immediately, when the guard is
opened. If not, do not use the machine; call supervisor and advise W & P Reedy.
4.6 Test the handle switch by lowering the bowl and then raising the bowl, then push the
green start button again. The mixer must stop operating immediately, when the bowl is
lowered. If not, do not use the machine; call supervisor and advise W & P Reedy.
4.7 During normal operation do not place any instruments or hands inside the mixing area or
around the planetary.
4.8 Never by-pass micro switches and run the machine while the guards are off.
4.9 Fully isolate machine from electric power source before cleaning.
5. Cleaning
5.1 When moving the mixer always use lifting trolley and appropriate procedures.
5.2 Brushing off all external surfaces. Using a soft brush working from top to bottom.
5.3 Wiping down the entire machine with a damp cloth, starting from the top to the bottom.
5.4 Cleaning of stainless steel bowl and attachments are to be cleaned with regular hot water
and detergent. Do not use abrasives as this can damage the bowls and attachments.