![Alyseum MS-MATRIX User Manual Download Page 12](http://html1.mh-extra.com/html/alyseum/ms-matrix/ms-matrix_user-manual_2915445012.webp)
MS-MATRIX – User’s manual © - Revision 1.8
Page 12
5.7 Factory
Reset
Be aware that a Factory Reset will erase all 32 Presets and all Settings stored by the user.
Additionally the expander mixer modules (MS-4VCAI and MS-4VCAO) will also undergo a
Factory Reset.
To perform a Factory Reset:
1. Turn the Eurorack case power off.
2. Push and hold both INPUT/SAVE and OUTPUT/LOAD encoders while turning the
Eurorack case power back on.
3. Release both encoders.
4.
RESET
will be displayed on the LED array.
5. The 32 Presets and all settings for MIDI and CV are erased.
6. System reset command (0xFF) is sent to slave modules via MIDI.
7. The initialization sequence begins (see paragraph 5.1).
5.8 MIDI
Bootloader
The MS-MATRIX is pre-programmed with the ability to receive firmware upgrades (for
bugfixes, extra features, customizations etc...) via MIDI protocol (SysEx commands).
Thanks to Olivier Gillet from Mutable Instrument for his open Bootloader code:
https://github.com/pichenettes/avr-midi-bootloader
.
In order to flash new firmware, please follow the instructions below:
1. Turn the Eurorack case power off.
2. Close all MIDI software on your computer.
3. Connect the computer and the MS-MATRIX with a MIDI cable.
4. Download Sys Ex utility at
http://www.elektron.se/support-and-downloads
(available
for WIN or OSX).