SP2.5R Installation Guide | TGrid | ATZ | Slot
SP2.5R Installation Guide | TGrid | ATZ | Slot
7 of 10
102-000011 - IG110218-B.0
12
Join miter sections
13
Screw connector brackets
14
Insert diffuser shim
Slide miter sections together and join section connectors.
Adjust connectors with set screws as necessary.
Screw connector brackets on top and sides with provid-
ed 8-32 screws avoiding any gaps between fixtures.
11
Connect wiring
Connect wiring quick-connects between fixture sections.
Installation: Joining Mitered Corners
Insert provided diffuser shim into slots in heat sink.
SHOCK HAZARD! May result in serious injury or
death.
Turn power OFF at circuit breaker prior to
installation or servicing.
!
DO NOT PINCH OR PUT EXCESSIVE TENSION ON
WIRES
while joining sections or reattaching end
caps.