Menus and Parameters
2-11
BreezeACCESS Version 4.5 System Manual
for storing it. Events are classified according to their severity level:
Trace
(lowest severity),
Message
,
Warning
,
Error
or
Fatal
(highest
severity).
The severity at which events are saved in the Event Log is
configurable. Events from the configured severity and higher are
saved and may be displayed upon request. Log history can be
displayed up to the full number of current active events. In the log
an event is defined as active as long as it has not been erased (a
maximum of 1000 events may be displayed). The error log may be
read using TFTP, with remote file name
<SNMP Read
Community>.log
(the default SNMP Read Community is
public
).
The
Event Log Menu
includes the following options:
"
Event Log Policy
– Determines the minimal severity level. All
events whose severity is equal to or higher than the defined
severity are logged.
Valid values are:
Log All (TRC) Level
,
Message (MSG) Level
,
Warning (WRN) Level
,
Error (ERR) Level
,
Fatal (FTL) Level
,
Log None
.
The default selection is
Fatal (FTL) Level
.
"
Display
Event Log –
Displays how many events are logged and
selects the number of events to be displayed (up to 1000). The
display of each event includes the event time (elapsed time since
last reset), the severity level and a message string. The events
are displayed in descending order, with the most recent event
displayed first.
"
Erase Event Log
– Clears the event log.
!
Auto Configuration Parameters
– A sub-menu that contains the
parameters related to using the Auto Configuration mechanism. The
Auto Configuration mechanism is intended to simplify the
configuration process through automatic loading of a configuration
file from a TFTP server. The Auto Configuration process is based on
getting from a DHCP server the address of the TFTP server and the
name of the configuration file to be loaded. This information is used
by the unit to initiate a session with the TFTP server, requesting
transfer of the applicable configuration file. Upon completing the
process of loading the new configuration file, the unit will reset
automatically so that the new configuration will take effect.
The following conditions must be met to enable the use of the Auto
Configuration process:
a. The
DHCP Option
(
see page 2-38
) in the unit must be
configured to either DHCP Only or Automatic mode to enable
communication with the DHCP server.
b.
The unit must be able to communicate with the DHCP server,
according to the configured option of the
Access to DHCP
parameter (
see page 2-38
).
Summary of Contents for BreezeACCESS II
Page 1: ...BreezeACCESS II System Manual SW Version 4 5 June 2004 P N 213801 ...
Page 2: ......
Page 15: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 1 System Description ...
Page 16: ......
Page 32: ...2 14 BreezeACCESS Version 4 5 System Description Manual Revision 1 0 ...
Page 46: ...3 14 BreezeACCESS Version 4 5 System Description Manual Revision 1 0 ...
Page 47: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 2 Installation ...
Page 48: ......
Page 80: ...2 8 BreezeACCESS Version 4 5 Installation Manual Revision 1 0 ...
Page 93: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 3 Commissioning ...
Page 94: ......
Page 110: ...2 8 BreezeACCESS Version 4 5 Commissioning Manual Revision 1 0 ...
Page 116: ...3 6 BreezeACCESS Version 4 5 Commissioning Manual Revision 1 0 ...
Page 126: ......
Page 257: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Appendices ...
Page 258: ......
Page 270: ...D 4 BreezeACCESS Version 4 5 System Manual Manual Revision 1 0 ...
Page 324: ...1 14 BreezeACCESS Version 4 5 Index Manual Revision 1 0 ...