Chapter 2 - Installation
Installing the Outdoor Unit
BreezeACCESS EZ AU-EZ
21
System Manual
2.3.4
Connecting the Indoor-to-Outdoor Cable
1
Unscrew the top nut from the waterproof seal.
2
Route a straight Category 5E Ethernet cable (8-wire, 24 AWG) through both
the top nut and the waterproof seal.
3
Insert and crimp the RJ-45 connector. Refer to
for instructions on
preparing the cable.
4
Connect the Ethernet cable to the outdoor unit RJ-45 connector.
5
Verify that the o-ring supplied with the waterproof seal is in place. Attach the
waterproof seal to the unit, and then tighten the top nut. Make sure that the
external jack of the cable is well inside the waterproof seal to guarantee a good
seal.
6
Route the cable to the location selected for the indoor equipment.
7
Assemble an RJ-45 connector with a protective cover on the indoor end of the
indoor-to-outdoor cable.
To connect the indoor-to-outdoor cable:
Figure 2-4: The Waterproof Seal
NOTE
Use only Category 5E 4x2x24# FTP outdoor cables from an approved manufacturer. See list of
approved cables and length limitations in
Summary of Contents for BreezeACCESS EZ AU-EZ
Page 1: ...BreezeACCESS EZ AU EZ System Manual Software Version 6 0 December 2009 P N 215449 ...
Page 20: ...1 Chapter System Description ...
Page 32: ...2 Chapter Installation ...
Page 43: ...3 Chapter Commissioning ...
Page 50: ...4 Chapter Operation and Administration ...
Page 148: ...A Appendix Software Version Loading Using TFTP ...
Page 152: ...B Appendix File Download and Upload Using TFTP ...
Page 155: ...C Appendix Using the Set Factory Defaults Utility ...
Page 157: ...D Appendix Preparing the Indoor to Outdoor Cable ...
Page 160: ...E Appendix Parameters Summary ...