Alvarion BreezeACCESS 900 Installation Manual Download Page 6

BreezeACCESS SU-M -900 Installation Guide 

   

 

vi

 

Radio 

The instrument transmits radio energy during normal operation. To avoid 
possible harmful exposure to this energy, do not stand or work for extended 
periods of time in front of its antenna. The long-term characteristics or the 
possible physiological effects of Radio Frequency Electromagnetic fields 
have not been yet fully investigated. 

Antenna Installation and Grounding 

Be sure that the antenna is properly installed to eliminate any physical 
hazard to either people or property. Make sure that the installation of the 
antenna and cables is performed in accordance with all relevant national 
and local safety codes.   

A good ground plane is necessary for optimal RF performance. 

 

Summary of Contents for BreezeACCESS 900

Page 1: ...BreezeACCESS 900 SU M 900 Installation Guide Preliminary...

Page 2: ...l or consequential damages in connection with the furnishing performance or use of this manual or equipment supplied with it Warranties Disclaimers All Alvarion Ltd Alvarion products purchased from Al...

Page 3: ...IFIED ABOVE AT ALVARION S OPTION TO THE FULLEST EXTENT ALLOWED BY LAW THE WARRANTIES AND REMEDIES SET FORTH IN THIS AGREEMENT ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS EXPRESS OR...

Page 4: ...ALL THE LIABILITY FOR DAMAGES HEREUNDER OF ALVARION OR ITS EMPLOYEES OR AGENTS EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT BY PURCHASER NOR SHALL THE AGGREGATE LIABILITY FOR DAMAGES TO ALL PARTIES...

Page 5: ...equirements in section 1 1307 a minimum separation distance of 20cm 8 inches is required between the antenna and all persons R TTE Compliance Statement This equipment complies with the appropriate ess...

Page 6: ...tics or the possible physiological effects of Radio Frequency Electromagnetic fields have not been yet fully investigated Antenna Installation and Grounding Be sure that the antenna is properly instal...

Page 7: ...n examples herein are fictitious unless otherwise noted Alvarion Ltd reserves the right to alter the equipment specifications and descrip tions in this publication without prior notice No part of this...

Page 8: ...cations 1 4 Configuration and Management 1 4 Connectors 1 5 Mechanical and Electrical 1 5 Environmental 1 5 Installation 2 1 Packing List 2 2 Items Required for Installation 2 2 Connecting the Unit 2...

Page 9: ...Table of Figures ix Installation Guide Table of Figures Figure 1 1 SU M 900 Unit 1 2 Figure 2 1 Connecting the Unit 2 5 Figure 2 2 SU M 900 Front Panel Connections 2 5...

Page 10: ...BreezeACCESS SU M 900 Installation Guide x...

Page 11: ...is chapter introduces the BreezeACCESS SU M 900 system It includes the following section Introducing BreezeACCESS SU M 900 page 1 2 introduces the SU M 900 and its functionality System Specifications...

Page 12: ...pecially designed to provide a constant network connection for law enforcement and emergency services personnel Figure 1 1 SU M 900 Unit NOTE The SU M 900 s case may only be opened by an authorized te...

Page 13: ...ompliance FCC Part 15 247 Channel Bandwidth 2 MHz Central Frequency Resolution 1 MHz SU M 900 Antenna 5 dBi close coil linear polarized omni directional Maximum Input Power at antenna port 20 dBm Outp...

Page 14: ...cess From Wired LAN Wireless Link Management Access Protection Multilevel password Configuration of remote access direction from Ethernet only from wireless link only or from both sides Configuration...

Page 15: ...ex DC plug Mechanical and Electrical Dimensions 30 x 20 x 12 cm 11 8 x 7 9 x 4 7 in Weight 4 5 kg 9 9 lbs Electrical 9 18 VDC 1A max Environmental Operating Temperature 10 C 14 F to 40 C 131 F Storage...

Page 16: ......

Page 17: ...system and includes the following sections Packing List 2 2 lists the items included with the SU M 900 Installing the SU M 900 Unit page 2 3 describes how to physically install the SU M 900 unit insi...

Page 18: ...d cable A 12 VDC power cable with 250 V 3 A fuse Items Required for Installation The following list comprised items required to install the SU M 900 that are not included with the installation package...

Page 19: ...of the mountin g holes in the unit as guides 2 Drill four holes in the surface using the marks you made 3 Clear all paint dirt and oil away from the area around the holes 4 If the SU M 900 unit is be...

Page 20: ...the assembly slightly and slipping it into the hole at an angle 5 Once the bushing assembly is inserted hold it in place either within the car from below the hole using a 1 2 Open Ended wrench or Adju...

Page 21: ...ts power supply Ethernet connection and antenna as shown in the figure below Figure 2 1 Connecting the Unit Figure 2 2 SU M 900 Front Panel Connections To connect theSU M 900 Unit 1 Once the SU M 900...

Page 22: ...is secure and out of the way for its protection 4 Connect the antenna cables to the omni antenna using an SMA Torque Wrench and then to the ANT 1 port on the SU M 900 Ensure that the cable is secure...

Page 23: ...BreezeACCESS SU M 900 and includes the following sections Configuration Applications page 3 2 provides an overview of how to change parameter settings Configuring Basic Parameters page 3 3 lists the...

Page 24: ...t port using a straight Ethernet cable Before running the Telnet program configure the PC s IP parameters to enable connectivity with the unit The default IP address is 10 0 0 1 Using BreezeCONFIG ACC...

Page 25: ...ftware DO NOT CHANGE USE ANT 1 PHYSICAL PORT ANT 2 NOT CONNECTED ESSID ESSID1 Must be the same as the ESSID the Base Station AU Hopping channels None Configure according to site survey results Best AU...

Page 26: ...ibes how to ensure that the SU M 900 unit is fully operational To verify unit operation 1 Verify that the PWR LED on the SU M 900 unit is lit 2 Confirm that the PC is operational 3 Send and receive a...

Reviews: