INSTALLATION AND OPERATION MANUAL. SDP PHOTOELECTRIC SENSOR

2

DESCRIPTION

1. 

DESCRIPTION

It is designed to signal about the blocking of operation to the control unit of loading equipment 

when the sectional doors are closed. The transmitter and receiver are located in a common 

compact Nickel-plated sensor body. The sensor output switches as soon as the door leaf enters 

the sensor operating area and the light is reflected.

2. 

TECHNICAL SPECIFICATIONS

Source voltage  ............................................................................................... 10 V…30 V direct current (DC)
Current consumption  ..............................................................................................................................≤ 25 mА
Output  .............................................................................. PNP NС (transistored, normally closed contact)
Maximum output load .............................................................................................................................  200 mА
Light source .............................................................................................................................. infrared (880 nm)
Maximum range  ....................................................................................................... 150 mm (factory setting)
Maximum response time  ...........................................................................................................................8,2 ms
Connection cable length  .................................................................................................................................6 m
Cable wire section  .................................................................................................................................. 0,14 mm

2

Protection class ........................................................................................................................................................ III
Protection degree  ............................................................................................................................................  IP67

Temperature range  ................................................................................................................ − 15 °C … + 55 °C

Weight  ............................................................................................................................................................  0,25 kg

 

Y

Company preserves the right to make changes in the present document and technical 

features of the product. The contents of this document cannot serve as basis for legal 

claims.

3. 

INSTALLATION AND OPERATION

Install the sensor in the vertical guide of the sectional doors. Before installation, determine the 

height of the sensor. The sensor must be installed at a height not lower than the maximum lift of 

the dock leveller; the maximum height of installation is limited to the full opening of the doors. 

To install the sensor at the selected height, drill a hole Ø 12 mm in the guide opposite the end 

surface of the door leaf. Determine the depth of the sensor installation on the guide and fix the 

sensor with two nuts. After installation, connect the sensor to the loading equipment unit 

(Fig. 2) 

and check its operation. When the light is reflected 

LED

 

(Fig. 1)

 illuminates, in the absence of 

reflection —  does not illuminate.

If it is necessary to adjust the range (sensing range) of the sensor, turn the 

VR

 screw. The end 

position of the 

VR

 screw during rotation anti clockwise is ~ 50 mm, the end position during 

rotation clockwise is ~ 150 mm.

BN

BK

BU

+V

DAT

GND

Wires:

BN

 — brown;  

BK

 — black;  

BU

 — blue

Figure 

1. Dimensions (mm)

Figure

 2. Connection