![Alula RE619 Quick Start Manual Download Page 2](http://html1.mh-extra.com/html/alula/re619/re619_quick-start-manual_2914624002.webp)
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
IC: 8310A-RE301
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by Alula could void
the user’s authority to operate this equipment.
FCC ID: U5X-RE301
WARRANTY
Alula will replace products that are defective in their first five (5)
years.
TRADEMARKS
Alula and are trademarks owned by Alula Holdings, LLC.
Panasonic is a registered trademark owned by Panasonic
Corporation.
Pro Tips
Both titanium probes
must be in the same puddle for the sensor to detect water.
A second probe
can be added for additional protection in another location. Do not
install more than two probes.
The flood probe
can be mounted in a sump tank at the desired height to provide pump
failure notification.
47-0021-08 • REV E • 2019-02-0
7
Tech Support Line • (888) 88-ALULA • (888) 882-5852
Physical
Housing Dimensions
Weight with Battery
Mounting Fastener
3.25 x 1.40 x 1.05 inches (8.3 x 3.6 x 2.7 cm)
1.90 ounces (54 grams)
#4 or #6 screws (not provided)
Environmental
Operating Temperature
Maximum Humidity
32 to 120 °F (0 to 49 °C)
85% non-condensing relative humidity
Sensor Specifications
Frequency
Replacement Battery
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
Temperature Accuracy
433.92 MHz
One Panasonic
®
CR123A
8 to 10 years
3.0 VDC (Nominal), 2.2 VDC (Low)
20 mA (Maximum), 0.6 uA (Quiescent)
Flood, Freeze, Heat, Tamper, Low Battery, Supervision
+/- 2°C
Certification
RE619
FCC, IC
Specifications subject to change without notice.
Specifications
00