Alula RE359 Manual Download Page 3

Troubleshooting

Problem

Probable Cause

Remedy

Alarm is not activated 

although someone is 

walking in detection 

area

Detection area is improper, 

battery is dead, Walk Test 

switch is OFF and 2 minute 

delay is active

Conduct a walk test, change 

the battery

Alarm is activated with 

nobody in the area

Moving object within 

detection area, temperature 

of object within area is 

changing rapidly

Remove the object from 

the detection area, remove 

the heat sources from the 

detection area or relocate the 

detector

LED does not light up 

at the time of the walk 

test

Walk test switch is OFF, 

battery is dead

Turn the walk test switch ON, 

change the battery

LED does not light up 

in normal operation

LED switch is OFF, battery 

is dead

Turn LED switch ON, change  

battery

Pro Tips

Save battery life 

by taking unit out of walk test mode after 

completing walk test. There is no 2 minute delay when 

in walk test mode. Leaving in walk test mode will 

severely decrease battery life.

Light changes 

will cause the sensor to trip. Ensure that the 

detector is not placed near windows. 

Sudden temperature changes 

will cause the sensor to trip. 

Ensure the motion detector is not placed near heating 

and cooling vents.

High humidity 

environments can cause condensation of 

the detection lens. Ensure the motion detector is not 

installed in these kinds of environments. 

Protective film 

should be removed from the lens after 

installation.

Sensor Specifications: 

The table below displays the 

functional frequencies of each compatible sensor.

Part Number Frequency

Compatible

RE159

319.5 MHz

Interlogix/Qolsys

RE259

345 MHz

Honeywell

RE259T

345 MHz

2GIG

RE359

433.92 MHz DSC