![Alula RE219 Quick Start Manual Download Page 1](http://html1.mh-extra.com/html/alula/re219/re219_quick-start-manual_2914615001.webp)
Use the panel installation guide to verify proper system setup.
The Home Disaster
is an integrated environmental sensor
that detects flood and extreme temperature conditions.
Features
•
Titanium probes for unmatched corrosion immunity
•
Detects flood, freeze, and heat conditions
•
Secure encrypted wireless transmissions
•
5-year warranty
Enroll
by placing the panel into wireless enrollment mode and
then sending an enrollment signal from the sensor.
Install
by placing the remote flood probe in the location
requiring flood or leak detection. If desired, the flood
probe can be screwed to the floor or baseboard. Next,
mount the sensor to the wall using the mounting screw
locations. Finally, connect the flood probe wires to the
sensor’s terminal blocks.
Detects
water pooled under the sensor and reports extreme
temperature conditions.
Default Temperature Trip Points
•
Heat alarms when over 100°F (38°C)
•
Heat restores when under 97°F (36°C)
•
Freeze alarms when under 45°F (7°C)
•
Freeze restores when over 48°F (9°C)
RE219 Home Disaster
™
Honeywell
®
Compatible
IN
STALL
G
U
I
D E
I
Mounting
Screw
Holes
Wire
Entry
Hole
Resolution Compatibles
Options for Sending an Enrollment Signal
•
Remove the battery tab and cover to trip tamper.
Program the loop number:
•
Loop 1: Heat
•
Loop 2: Flood
•
Loop 3: Freeze
•
Loop 4: Tamper