Alula RE210T Install Manual Download Page 2

Pro Tips

Walk test mode

 is entered by pressing the motion

 

sensor’s tamper button.  The walk test lasts three 

minutes.

Walk Test Operation

•  The walk test LED turns on when motion 

is sensed.

•  The motion sensor performs a             

re-calibration after each activation.  The 

re-calibration takes about 30 seconds.  

The sensor will NOT sense motion 

during the re-calibration.

•  Wireless  transmissions  are  sent  for  each              

detection, so walk test mode can also 

be used to test the panel. 

3M VHB tape 

works great if the surface is properly 

prepared and firm pressure is applied for over 10 

seconds.

Surface Preparation

•  Clean the surface

•  Ensure the mounting surface 

temperature is above 50 °F

Motion lockout 

is active for three minutes after a motion event is detected.  During the 

motion lockout period, motion events will be ignored.

Motion sensitivity

 can be adjusted by the sensitivity jumper on the circuit board.   

•  Jumper Installed (lower sensitivity):  Detects person in 3 to 5 steps. 

Increases pet immunity. Usually for security applications.

•  Jumper NOT Installed (higher sensitivity): Detects person in 2 to 4 steps. 

Usually for occupancy applications.

Walk Test LED

Cover Tamper Switch

Battery

Bug Foam IR Sensing Element

Sensitivity

Low - Jumper ON

High - Jumper OFF

External Contact

Install

 using the included 3M VHB

®

 tape to adhere the motion 

sensor on a wall or in a corner.  The tape should be applied 

to the 

back

 when wall mounting or to the 

back bevels

 when 

corner mounting.  Alternatively, screw mounting can be done 

by punching out the screw mounting holes.

Installation Tips

• 

Mount 7.5 to 9.5 feet from the floor for an optimal 

balance between catch performance and pet 

immunity.

•  Remove the cover and circuit board before trying 

to punch out the screw mounting holes.

•  Ensure the bug foam stays intact and snug around 

the IR sensing element when re-installing the 

circuit board.

External Contact

 

(not evaluated by ETL)

•  Use a 

normally-closed 

contact because the motion sensor will transmit an 

alarm when it sees the external contact 

open

.

•  Do not use end-of-line resistors.

Mounting Screw Holes