Walk test mode

 is entered by pressing the motion

 

sensor’s tamper button.  The walk test lasts three 

minutes.

Walk Test Operation

•  The walk test LED turns on when motion 

is sensed.

•  The motion sensor performs a             

re-calibration after each activation.  The 

re-calibration takes about 30 seconds.  

The sensor will NOT sense motion 

during the re-calibration.

•  Wireless  transmissions  are  sent  for  each              

detection, so walk test mode can also 

be used to test the panel. 

3M™ VHB™ tape 

works great if the surface is 

properly prepared and firm pressure is applied for 

over 10 seconds.

Surface Preparation

•  Clean the surface

•  Ensure the mounting surface 

temperature is above 50 °F

Motion lockout 

is active for three minutes after a motion event is detected. Motion 

events will be ignored during the motion lockout period.

Motion sensitivity

 can be adjusted by the sensitivity jumper on the circuit board.   

•  Jumper Installed (lower sensitivity):  Detects person in 3 to 5 steps. 

Increases pet immunity, usually for security applications.

•  Jumper NOT Installed (higher sensitivity): Detects person in 2 to 4 steps. 

Usually for occupancy applications.

Pet immunity

 

is optimized when the motion sensor is mounted at 7.5 to 9.5 feet high 

and aimed 

away

 from house features that could allow pets to be high in the detection 

field (e.g. stairs, counter tops, tall furniture).

Motion catch performance

 is best when the motion sensor is positioned so a person 

would typically walk across the front of the motion sensor instead of directly toward 

the motion sensor.

Motion Detection Tip

s

•  Provide a clear line-of-sight to the monitored area and remember that glass 

blocks infrared energy.

•  Aim away from windows and sunlight.

•  Aim away from air conditioners, heaters or heating/cooling vents.

Walk Test LED

Cover Tamper Switch

Battery

Bug Foam IR Sensing Element

Sensitivity

Low - Jumper ON

High - Jumper OFF

External Contact

7.5ft

0

0

10ft

20ft

30ft

40ft

3.2ft